User manual
User Manual – Rev B FCS Series II
VOLT FREQ MAX
This test will set the voltage and frequency to a level defined by Table 8-9. The test will last for
tes. The test will be repeated using the voltage from Table 8-8and frequency from Table
8-9. The ← key (backspace) will terminate the test at any time.
VOLT UNBALANCE
30 minu
Standard/Group RTCA A(CF) A(NF) A(WF)
Voltage offset 8 10 8 8
Frequency 400 360/800 360/440 360/650
Standard/Group Group1 Group2 Group3
Voltage offset 8 8 12
Frequency 400 360/650 360/800
Table 8-10: Emergency Voltage Unbalance
This test will change the output voltage for phase A and B to 122V and phase C to a voltage
lower by a value specified by an offset. Refer to Table 8-10 for the offset value and the
frequency and phase A and B volt is set to 100V
y the offset. The test will last 30 minutes. The
test will be repeated for a second Frequency if applic
time.
The ← key (backspace) will terminate the test at any time.
Frequency. The test will repeat with the same
and phase C set to a higher voltage specified b
able. The test can be terminated at any
California Instruments 124