Instruction manual
76
ARGUMENT EXT DATA
REPORTED
DEFINITION
PWR A, B, C 0 to MAX POWER Output KW
PZM A, B, C 0 to 359.9 Measured phase B and C output phase angle
relative to A. A is always 0.0
REG 0 to 15 Contents of Reg Talk contents of register
RNG None 0 to 270.0 Programmed range and limit
SRQ None 0, 1 or 2 Programmed SRQ status
VLT A, B, C 0.0 to 400.0 Measured output voltage
(*) Standard values shown. Values will be different for other ranges, output power and
options.
NOTE: If the A, B or C Extension is not sent with the argument, all phases will
be reported.
MAXIMUM CURRENT (PER PHASE)
VOLTAGE RANGE
MODEL 135 156 270 312 400
FCS-18/1-3 44.4 38.4 22.2 19.22 15.0
FCS-18/1-1 133.2 115.2 66.6 57.6 45.0
FCS-36/2-3 88.86 76.92 44.40 38.4 30.0
FCS-36/2-1 266.4 230.7 133.2 115.2 90.0
FCS-54/3-3 133.2 115.4 66.6 57.6 45.0
FCS-54/3-1 399.6 346.2 199.8 173.1 135.0