Instruction manual
63
Table 3-12: Program Headers
HEADER EXTENSION ARGUMENT DEFINITION
AMP A, B, C # or numeric from
0.0 to RNG value
Amplitude in volts.
CAL A, B, C 0 - 255 Calibrated the output voltage.
CAL VLT A, B, C Actual voltage Calibrated measured voltage at
external sense point.
CAL CUR A, B, C Actual current Calibrate measured current.
CAL PWR A, B, C Actual power Calibrate measured power.
CRL A, B, C 0 to maximum Current limit in amps current per
phase
DLY 0.000 to 9999 Delay in seconds used as a seconds
ramp parameter.
FRQ 45.00 to 1200 Frequency in hertz.
PHZ A, B, C 0 to 999.0 Phase angle in degrees.
PRG 0 through 15 Load register with preceding data.
REC 0 through 15 Recall register or specify link
register if it is preceded by program
argument followed by PRG and
register number.
REG 0 through 15 Register load.
RNG A, B, C 0.0 to maximum
range value
Amplitude and limit volts.
SNC INT,EXT Synchronize.
DRP A, B, C 1 through 5 Number of Drop cycles.
SRQ 0, 1 or 2 Service Request disable, enable or
at completion of program and
measurements
STP From parameter
minimum to
maximum value
Define step size in ramp.
TLK Any header Set up to talk argument value or
measured value when addressed to
talk.