Instruction manual

48
3. Select the RMP A screen and specify the ramp parameters of the independent
parameter, FRQ, of DLY = .2 seconds, STP = .2 Hz and VAL = 440 Hz:
9 ENT A 0.2 PRG B 0.2 PRG C 440 PRG
4. Select the RMP B screen and specify the ramp parameter of the dependent
parameter, AMP, of STP = .5 volts:
10 ENT B 0.5 PRG
5. At this point the program may be executed by depressing the ENT key or stored
in a register.
3.5.3.10.DROP PERIODS (DRP=2)
Select the phase (PHZ) screen by entering the keystrokes:
7 ENT
The display will show the PHZ parameter screen
PHZ MON A = 0.0 B = 240.0 C = 120.0
To drop the Phase A output waveform starting at 90 degrees, enter the keystrokes 90 A PRG.
Select the Drop screen (DRP=2) by entering the keystroke 2 ENT.
The display will show the DRP parameter screen.
DRP MON A = 0 B = 0 C = 0
To drop the output waveform for phase A for 3 periods enter, the keystrokes:
3 A PRG ENT
Verify that phase A drops at the 90 degree point of the sine wave for 3 periods of the
programmed output frequency.
3.5.3.11.DEFAULT VALUES
The default values are the values for Frequency, Voltage, Voltage Range and Current Limit
that appear at power-up and after the GPIB Device Clear command.