Instruction manual

35
Table 3-5: Output Parameter Screen
NO. SCREEN
NAME
EXT. ARGUMENT ACTION TAKEN
The following are for changing the output:
1 SNC INT, EXT Selects phase A to be synchronized to an
external input.
2 DRP A, B, C 1 - 5 Set the number of Drop Cycles. PHZ A
value will define the start point of the drop
cycle.
4 RNG Range limit Sets the output voltage limit value below
the maximum limit. Selects output voltage
range (PRC Option).
5 AMP A, B, C 0-RNG limit Sets the output voltage amplitude.
6 FRQ 45-1200 Sets the output frequency.
7 PHZ A, B, C, 0-±999.9 Sets the output phase angle.
8 CRL A, B, C 0 to MAX
current
Sets the output current limit.
9 RMP A DLY 0.001-9999 Sets the Delay between ramp steps in
seconds. Four decade resolution from
0.001 to 9999 seconds.
STP Sets the step size of ramp parameter.
VAL Sets the final value of the parameter
ramped.
RMP B STP Same as RMPA
VAL Same as RMPA
30 MOD PHS1 or PHS3 Selects output to be 1 phase or 3 phase.
NOTE: RMPA and RMPB screens are not accessible until AMP, FRQ, CRL or
PHZ are programmed (PRG) but not yet entered (ENT).