Instruction manual
25
The right subpanel has a liquid crystal display and a REMOTE lamp.
The liquid crystal display shows the numeric value of all programmed output parameters. It
also shows all error messages and measured values.
The REMOTE lamp illuminates when the AC power system has been addressed through the
IEEE-488 interface (GPIB).
3.4. REAR PANEL CONNECTIONS
(Refer to Figure 3-2 for all rear panel connections.)
3.4.1. POWER INPUT
TB1 is the terminal block for the 3-phase input voltage. Terminals 1, 2 and 3 connect to
each leg of the 3-phase input. Terminal 4 is the chassis connection which should be
connected to the input mains ground.
3.4.2. POWER OUTPUT
TB3 is the power output terminal block. Refer to Table 3-1 for identification of the TB3
terminals. Refer to Figure 2-2 for the output of all multiple power source power systems.
Table 3-1: Terminal Identification
TB3 DESCRIPTION
1 Phase A Output HI
2 Phase B Output HI
3 Phase C Output HI
4 Output Neutral
3.4.3. EXTERNAL SENSE
TB2 is the external sense input connector. The external sense input of the master power
source must be connected to the respective AC Power System output. If the inputs are not
connected, an OUTPUT FAULT error message will be generated. Table 3-2 identifies the
pins of connector TB2.
Table 3-2: Connection Identification
TB2 DESCRIPTION CONNECTION
1 Phase A Sense HI Phase A Output HI
2 Phase B Sense HI Phase B Output HI
3 Phase C Sense HI Phase C Output HI
4 Neutral Sense Neutral Output