Instruction manual
121
8. MIL-STD-704D
8.1. GENERAL
The MIL-704D option is capable of performing all sections of MIL-STD-704D. It will perform
all tests in the order listed below or part of the test. There is a 5 second delay between tests to
allow the operator to evaluate the result of the test.
8.2. INITIAL SETUP
Nominal parameters for the AC Power Source shall be as follows:
OUTPUT VOLTAGE: 115 L-N
OUTPUT FREQUENCY: 400
OUTPUT PHASE ANGLE: B 240
C 120
8.3. TEST PERFORMED
8.3.1. STEADY STATE TEST. (REFER TO MIL-704D DOC. TABLE 1)
1. Voltage per Figure 1, page133.
2. Voltage unbalance per Figure 2, page 133.
3. Voltage phase difference per Figure 3, page 133.
4. Waveform distortion factor per Figure 4, page 133.
5. Frequency per Figure 5, page 133.
8.3.2. TRANSIENT
1. Voltage Transient (Refer to MIL-704D Doc. Figure 5.)
High voltage Transient per Figure 6, page 134.
Low voltage Transient per Figure 7, page 134.
2. Frequency Transient (Refer to MIL-704D Doc. Figure 6, page 131)
High frequency Transient per Figure 8, page 135.
Low frequency Transient per Figure 9, page 135.