User manual
Compliance Test System 3.0 User Manual
Frequency may not be 50Hz depending on power source used and
application.
15.4 Environmental
Parameter Specification
Operating Temp: 0 degrees to +40 degrees Celsius.
Storage Temp: 0 degrees to +70 degrees Celsius.
Humidity:
Operating:.
≤90% RH up to 40° C
Storage:
≤90% RH up to 40° C, ≤75% RH up to 70° C.
Creepage and
Clearance: Rated for Pollution Degree 2.
Insulation: Rated to Installation Category(Overvoltage Category) II
Vibration: Designed to meet NSTA 1A transportation levels.
Shock: Designed to meet NSTA 1A transportation levels.
15.5 Regulatory
Parameter Specification
Electromagnetic Emissions and
Immunity:
Designed to meet EN50081-1 and EN50082-1
European Emissions and Immunity standards as
required for the “CE” mark.
Acoustic Noise: 60 dBA maximum. Measured at one meter. (PACS-X
or 1251RP)
75 dBA maximum. Measured at one meter. (5001iX)
Safety: Designed to meet EN61010-1 European safety
standards as required for the “CE” mark.
146 Revision N California Instruments