10. IEC 61000-4-17 DC Ripple Immunity Testing
Figure 10-1: IEC 61000-4-17 Test Window
10.1 About This Chapter
This chapters covers testing a device for compliance with the IEC 61000-4-17 DC Voltage Ripple
test standard. This test is supported through the CIGui32 or CIGuiSII AC source control program.
If you purchased a 100-CTS or 300-CTS test system which does not include a California
Instruments AC source or the CTS system uses an RP Series AC source, you will not be able to
perform these tests.
The IEC 61000-4-17 implementation in the CIGUI32 or CIGuiSII is based on the IEC 61000-4-17
standard dated 1999-06. Test levels and ripple frequency can be changed if needed or set to
one of the pre-defined test levels.
116 Revision N California Instruments