Specifications
Specifications
California
Instruments
Total Customer Satisfaction is
the goal of all California
Instruments’ employees. It is the
driving force behind everything
we do. This not only affects the
product that you purchase from
California Instruments, but
everything about your interface
with the company. Our
applications engineers are
ready to assist you with your AC
power application. With over 35
years of experience designing
and building precision AC power
supplies, chances are we can
meet your needs and exceed
your expectations. The same
dedication to customer
satisfaction you will find in our
applications group also
permeates our modern
manufacturing facility where our
products are carefully built. No
unit leaves our factory without
being thoroughly tested to
ensure quality, reliability and
conformance to specifications.
CE Mark
The 801RP and 1251RP have
been fully tested for compliance
with 1997 CE Mark requirements.
This allows both AC power sources
to be used in the European
Economic Community.
Parameter 801RP 1251RP Unit
Controller
Type Programmable
Controls Digital Encoders
Readout Voltage 4 digit LCD
Freq. / Current 4 digit LCD
Non Volatile Setups (with -IF option) 8
Output
AC Power 800 1250 VA
Voltage
High range 0 - 270 V (L-N)
Low range 0 - 135 V (L-N)
Accuracy @ 50/60 Hz ± 1 % FS
@ 400 Hz ± 2 % FS
Resolution 0.1 V
Line & Load Regulation High V range ± 0.5 % FS
(combined) Low V range ± 1 % FS
T.H.D. @ 50/60 Hz 0.5 typical %
Output Noise < 0.1 typical V
Frequency (specifications valid from 45 Hz to 500 Hz)
Range 16 - 500 Hz
Accuracy ± 0.02 %
Resolution below 100 Hz 0.1 Hz
above 100 Hz 1 Hz
Current
Steady State Current High V range 3.0 4.6 A rms
Low V range 6.0 9.2 A rms
Peak Current High V range 13.8 13.8 A peak
(shorted output) Low V range 27.6 27.6 A peak
Protection
Current limit Mode Programmable
(Output shut off) Resolution 0.1 A rms
Over Temperature
√
Over Voltage
√
Input
Line Voltage
1
Nominal 2 wire + GND 100 -240 V rms
Maximum operating range 85 - 265 V rms
Line Current (fused) < 15 A rms
Line Frequency 47 - 63 Hz
Holdup Time 20 ms
Power Factor > 0.95 typical
Isolation Input to Chassis 1350 V
Input to Output 2200 V
Measurements
Current Range 0.0 - 10.0 A rms
Accuracy ± 0.2 A rms
Resolution 0.1 A
Voltage Range 0 - 278 V
Resolution 1 (below 250 V) V
Remote Control Option
Interface types option -IF RS232C
IEEE-488
IEEE-488 Address 0 - 31
IEEE Functions SH1, AH1, T6, L3, RL2
RS232C settings 9600,8,n,1
Command Language SCPI
Physical
Regulatory CE
Dimensions HxWxD 3.5 x 16.8 x 22 inches
HxWxD 89 x 427 x 560 mm
Weight (net) 34 / 15.4 lbs / kg
Vibration and Shock Designed to meet NSTA-1A
Temperature Operating 0 to 40 ° C
Storage - 40 to + 85 ° C
1
120 Vrms minimum line input required for full 1250 VA output on model 1251RP.
Note: Specifications shown are valid over an ambient temperature range of 25°±5°C.