StyleTherm™ TO-TH2-XX & TO-THC2-XX ½” Thermostatic Valve with Dual Volume Control Trim Installation Instructions TH52-R (ROUGH) TO-TH2-XX_ii_130102.
CALIFORNIA FAUCETS RECOMMENDS THAT ALL PLUMBING PRODUCTS BE INSTALLED BY A LICENSED PROFESSIONAL 1 • • TEMPERATURE SETTING Remove SCREW (2), WASHER (3), MUDGUARD (4) and SLEEVE (5) from installed VALVE (1) Push plastic TEMPERATURE LIMIT STOP (6) onto THERMOSTATIC CARTRIDGE (7) as shown • Temporarily place BONNET (8) THERMOSTATIC CARTRIDGE STEM (7a) • Place STEM (19) onto STOP/VOLUME CONTROL (19a) and using PHILLIPS SCREWDRIVER (19C) secure STEM (19) with SCREW (19b) • With both hot and cold water su
MAINTENANCE The thermostatic cartridge has built-in screens to prevent debris from affecting proper operation of anti-scald protection. Debris may build up on screens this will affect water flow and will require occasional service.
FINISH CARE See complete finish care instructions at www.calfaucets.com • Wipe dry after each use with a soft dry cloth to prevent water-spotting and mineral build-up • Clean and wax regularly o For Living Finishes (e.g. Weathered Brass, Weathered Copper, Oil Rubbed Bronze, Rustico Bronze) we recommend Renaissance Wax o For all other finishes, we recommend Faucet Brite, which contains both gentle cleansers and a fine wax coating.