3.11.2. Names/Profiles
The Names/Profiles menu provides input masks to rename the generic input channels and user names.
User names and input channel names can be changed to any word with a maximum of 12 alpha
numeric characters with a value range of 0-9, A-Z and blank.
The Names/Profiles menu allows the user to store profiles under a certain user name. It also allows to
copy user profiles by loading a profile stored under one user name and save it under another user
name.
Reset Profile allows to restore default HQView-5xx settings for the currently selected user.
3.11.3. Input Config
Inputs can be configured through the following sub-menus:
VGA Setup:
Submenu for adjusting analogue computer video.
A button for automatic setup of frequency and phase of the sampling clock is provided. This automatic
adjustment is strongly recommended.
Frequency (Clock) and phase can also be altered manually.
The preferred video mode can be selected in the EDID Input Format menu. This setting can force the
source to output a certain video mode.
DVI Setup:
The DVI-I connector will accept either DVI-D or VGA analogue inputs. The DVI-I channel can be
configured for either.
The equalisation of the DVI interface can be boosted to allow for extended cable length.
The automatic DVI Color Space and Range settings can be overwritten in this menu. Range can be set
to limited video mode or full range. The color space can be set to RGB or YCbCr.
The DVI Port EDID by default is a DVI EDID, but can be overwritten by a HDMI EDID. Thus, audio and
more video modes also with deep color become available.
When in HDMI mode (HDMI EDID loaded) the audio capabilities of the port can be configured by means
of overwriting the EDID yet again. HQView is part of an audio/video processing chain and devices
behind HQView may not be able to cope with advanced audio. HQView can signal the source to match
with the audio capabilities of the display, or to be S/PDIF friendly or to be SDI friendly.
The preferred video mode can be selected in the EDID Input Format menu. This setting can force the
source to output a certain video mode.
HDMI Setup:
The automatic HDMI Color Space and Range settings can be overwritten in this menu. Range can be
set to limited video mode or full range. The color space can be set to RGB or YCbCr.
The audio capabilities of the HDMI port can be configured by means of overwriting the EDID. HQView is
part of an audio/video processing chain and devices behind HQView may not be able to cope with
advanced audio. HQView can signal the source to match with the audio capabilities of the display, or to
be S/PDIF friendly or to be SDI friendly.
The preferred video mode can be selected in the EDID Input Format menu. This setting can force the
source to output a certain video mode.
SDI Setup:
For 3GSDI Level A or B type input modes can be chosen.
SDI audio input is routed to the HDMI and 3GSDI output connector by default.