Specifications

MAINTENANCE
47
Tennant 5300 (1100)
8. After the charger has turned off, unplug the
charger from the wall outlet.
9. Unplug the charger connector from the
battery connector on the machine.
FOR SAFETY: When servicing machine, avoid
contact with battery acid.
10. After charging batteries, check the
electrolyte level (B) in each battery cell. Add
just enough distilled water to bring the
electrolyte level (B) up to 1cm (0.38 in.) from
bottom of the fill rings (C).
11. Lower the recovery tank.
12. Rotate the stop arm out of the way to allow
the recovery tank to close completely.
SCRUB HEAD
The scrub head encloses the scrub brush and a
solution dispensing system. The scrub head skirt
controls over-spray from the scrub brush. Make
sure the scrub head skirt touches the floor all the
way around when the scrub head is lowered.
Check the skirt for damage or wear daily.
ADJUSTING THE SCRUB HEAD SKIRT
1. Turn the machine power off.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.
2. Lower the scrub head.
3. Check to see if the scrub head skirt touches
the floor all the way around the scrub head.
09521
B
C
09522