Tennant 5300 (0398)
Never add acid to the batteries, only distilled
water. Always keep the battery caps on, except
when adding water or taking hydrometer readings.
Measuring the specific gravity using a hydrometer
is a way to determine the charge level, and
condition of the batteries. If one or more of the
battery cells test lower than the other battery cells
(0.050 or more), the cell is damaged, shorted, or
is about to fail.
NOTE: Do not take readings immediately after
adding distilled water. If the water and acid are not
thoroughly mixed, the readings may not be
accurate. Check the hydrometer readings against
the following chart to determine the remaining
battery charge level:
SPECIFIC GRAVITY BATTERY
at 27_ C (80_ F) CHARGE
1.265 100% Charged
1.223 75% Charged
1.185 50% Charged
1.148 25% Charged
1.110 Discharged
NOTE: If the readings are taken when the battery
electrolyte is any temperature other than 27_ C
(80_ F), the reading must be temperature
corrected. Add or subtract to the specific gravity
reading 0.004, 4 points, for each 6_ C (10_ F)
above or below 27_C (80_ F).
CHARGING THE BATTERIES
1. Drive the machine to a flat, dry surface in a
well-ventilated area.
2. Turn the machine power off and set the
parking brake if your machine has this
option.
FOR SAFETY: Before leaving or servicing
machine, stop on level surface and turn off
machine.