Install Instructions

4
2 Safety instructions
The installation and commissioning of the solar station as well as the connection of electrical
components requires technical knowledge matching with a recognized vocational qualification
as a pipe fitter for plumbing, heating and air conditioning technology, or a profession requiring a
comparable level of knowledge. The following must be observed during installation and
commissioning:
x the relevant state and national regulations
x the accident prevention regulations of the trade association
x the technical and safety instructions of these instructions
Attention: Risk of scalding
There is a danger of steam emission with safety valves. Therefore a
discharge pipe must be connected to the ¾" internal thread of the safety
assembly. Please observe the enclosed instructions regarding the safety
valve when doing this.
Attention: Damage to property
The group of fittings must be installed with sufficient spacing to the
collectors because temperatures in the vicinity of the collectors can be
very high. An intermediate vessel may be necessary for installation in the
attic.
Attention: Damage to property
It is imperative that you make sure the EPDM sealing elements of the
solar station do not come into contact with substances containing mineral
oil. Mineral oil products cause lasting damage to the material, whereby its
sealant properties are lost.
If necessary, ask the manufacturer whether the solar fluid, contains fats
or installation aids contain mineral oils.
We do not assume liability nor provide warranty for damage to property
resulting from seals damaged in this way.