Brochure

12131218
69
Balancing valve with fl ow meter.
Direct reading of fl ow rate.
No sight gauge clouding or scaling.
Low-lead brass valve body and fl ow meter.
Rotatable stainless steel fl ow rate adjuster.
Inlet fl ow check valve.
Graduated scale fl ow meter with magnetic
movement fl ow rate indicator.
Reduction of Lead in Drinking Water Act
Compliant: 0.25% Max. weighted average
lead content. Reduction of Lead in Drinking
Water Act Certifi ed by IAPMO R&T
6HSGHMRTK@SHNM
Max. working pressure: 150 psi.
Temperature range: 14—230°F.
Max. percentage of glycol: 50%.
132
QuickSetter+
tech. broch. 01283
NEW
NEW
Code Description Flow scale (gpm) Pk Lbs USD
132439AFC ½" Sweat 0.5—1.75 1 2.0 288.00
132539AFC ¾" Sweat 0.5—1.75 1 1.8 310.00
132639AFC 1" Sweat 0.5—1.75 1 2.4 357.00
132459AFC ½" Sweat 2.0—7.0 1 2.0 288.00
132559AFC ¾" Sweat 2.0—7.0 1 1.8 310.00
132659AFC 1" Sweat 2.0—7.0 1 2.4 357.00
Code Description Flow scale (gpm) Pk Lbs USD
132438AFC ½" Sweat 0.5—1.75 1 2.4 338.00
132538AFC ¾" Sweat 0.5—1.75 1 2.2 360.00
132638AFC 1" Sweat 0.5—1.75 1 2.8 407.00
132458AFC ½" Sweat 2.0—7.0 1 2.4 338.00
132558AFC ¾" Sweat 2.0—7.0 1 2.2 360.00
132658AFC 1" Sweat 2.0—7.0 1 2.8 407.00
F19346 Replacement by-pass valve stem* 1 0.1 48.80
*with operating ring
cold
water
supply
recirculation
pump
check
valve
.5 GPM
.5 GPM
.5 GPM
!@K@MBHMFL@CDE@RSD@RX@MC@BBTQ@SDVHSG0THBJ2DSSDQ
Hot water recirculation systems are designed to minimize wait
time for hot water to arrive when a fi xture is opened. Systems left
unbalanced or improperly balanced result in wasted water down
the drain – a costly and environmentally unfriendly situation. Not to
mention the undesired annoyance placed on building occupants.
Caleffis popular QuickSetter+™ takes guess work and labor out of
balancing. With the valve’s exclusively designed venturi mechanism,
the installer simply:
1. pulls the fl ow indicator by-pass pin
2. adjusts the fl ow to the desired gpm while viewing the
built-in sight gauge
3. releases the pin
Easy, accurate balancing in seconds. No instruments or reference
graphs needed.
Features include:
t5ISFFDPOOFDUJPOTJ[FT£BOETXFBUVOJPO
t5XPnPXSBOHFPQUJPOTHQNTDBMFPSHQNTDBMF
t4UBJOMFTTTUFFMnPXBEKVTUFS
t.FNPSZnPXJOEJDBUPS
t#VJMUJOnPXDIFDLWBMWF
t5FNQFSBUVSFHBVHF
t*"1.0DFSUJmFEMPXMFBE
+.6+$ #! + -"(-&5 +5$6(3'%+.6,$3$1
cold
water
supply
recirculation
pump
check
valve
1 GPM .5 GPM trickle
Balanced example
4MA@K@MBDCDW@LOKD
6HSGSDLODQ@STQDF@TFD