Brochure

104
10
B
GeoCal left hand distribution manifold
assemblies with temperature gauges, air
vents and drain valves.
1¼" F NPT brass inlet/outlet ports.
Max. working pressure: 90 psi.
Max. system test pressure: 150 psi.
Working temperature range for: water,
glycol & saline solutions: 15—140ºF.
ethanol & methanol solutions: 15—90ºF.
Ambient temp. range: -5—140ºF.
Max. fl ow rate: 24 gpm total all circuits.
110
GeoCal
Code Description Pk Lbs USD
1107B5LA Left side connections, 2 circuits 1 16 1,260.00
1107C5LA Left side connections, 3 circuits 1 18 1,390.00
1107D5LA Left side connections, 4 circuits 1 20 1,530.00
1107E5LA Left side connections, 5 circuits 1 22 1,660.00
1107F5LA Left side connections, 6 circuits 1 23 1,790.00
1107G5LA Left side connections, 7 circuits 1 25 1,950.00
1107H5LA Left side connections, 8 circuits 1 26 2,080.00
Code Description Pk Lbs USD
1107B5RA Right side connections, 2 circuits 1 17 1,260.00
1107C5RA Right side connections, 3 circuits 1 18 1,390.00
1107D5RA Right side connections, 4 circuits 1 20 1,530.00
1107E5RA Right side connections, 5 circuits 1 22 1,660.00
1107F5RA Right side connections, 6 circuits 1 23 1,790.00
1107G5RA Right side connections, 7 circuits 1 25 1,950.00
1107H5RA Right side connections, 8 circuits 1 26 2,080.00
GeoCal right hand distribution manifold
assemblies with temperature gauges,
air vents and drain valves.
1¼" F NPT brass inlet/outlet ports.
Max. working pressure: 90 psi.
Max. system test pressure: 150 psi.
Working temperature range for: water,
glycol & saline solutions: 15—140ºF.
ethanol & methanol solutions: 15—90ºF.
Ambient temp. range: -5—140ºF.
Max. fl ow rate: 24 gpm total all circuits.
The GeoCal
pre-assembled manifold for ground-source geothermal
loops offers an alternative method of piping parallel earth loops, bringing all
circuits to a common manifold station without labor-intensive fusion welding.
GeoCal™ allows easy individual circuit balancing. Shut-off ball valves
installed on the return manifold allows for easy individual circuit purging and
requiring a smaller purge/fi ll pump then traditionally used.
Manifold assemblies include supply and return manifolds, automatic air
vents, dual-scale temperature gauges, fi ll/drain valves, brass end caps with
insulation, wall brackets with mounting hardware and labels.
GeoCal™ manifold assemblies can be installed indoors, or in an outdoor
vault.
1. Manifold outlet
tting 110050A/60A*
2. Ball valve NA39589/NA39753*
3. Ball valve NA39588
4. GeoGrip™ ball valve NA10268
5. Optional insulation shells for
Isolation valves with inlet/outlet
ttings 111001/003*
6. GeoGrip™ pipe coupling
861527A/634A*
7. QuickSetter™ 132552A/662A*
8. QuickSetter™ 132772A
9. Double nipple NA10263
10. GeoGrip™ male adapter NA10269
11. Insulation sleeve, 132552A and
ttings 110050A and 861527A
Insulation sleeve, 132662A and
ttings 110060A and 861634A
12. GeoGrip™ manifold to earthloop
pipe connector NA10246/247*
13. GeoGrip™ sleeve coupling
863027/034*
14. GeoGrip™ poly sleeve coupling
for joining 1¼" x 1¼" PE
piping NA863042
15. GeoGrip™ elbow NA866042,
1¼" x 1¼"
16. GeoGrip™ elbow NA866027/034*
17. Vent cap adapter NA10204
18. GeoSeal™ wall penetration seal
NA10248/NA10249*
19. GeoSeal™ wall penetration seal
NA10265
20. Air vent for manifolds
502043 CST
21. Manifold temperature gauge
687000
22. Drain valve 538402 FD
*
Part numbers fi ts ¾" and 1" sizes
120
100
80
60
40
20
0
-20
F
120
100
80
60
40
20
0
-20
F
CALEFFI
7
6
5
4
3
2
230°F
3/4” NPT
GPM
150 psi
CALEFFI
7
6
5
4
3
2
230°F
3/4” NPT
GPM
150 psi
20
2
22
21
1
3
4
5
6
7
8
9
10
11
12
13
15
14
16
17
18
19
1
6
tech. broch. 03175
Function