Product Overview

SPECIFICATION SUMMARY
Calef North America, Inc.
3883 W. Milwaukee Rd
Milwaukee, WI 53208
Tel: 414-238-2360 · Fax: 414-238-2366
sales@calef.com · www.calef.com/usa/en-us
© Copyright 2014 Calef
We reserve the right to change our products and their relevant technical data, contained in this publication, at any time and without prior notice.
Code 559920A
HydroLink hydraulic separator plus distribution manifold header with built-in wall mounting, branches 2+0, for heating systems. Painted
seel body with pre-formed insulation. Main connections (to primary) 1 inch NPT female, center distance 2-3/8 inch (60 mm); connections
to branches (secondary) 1 inch NPT male, center distance 4-15/16 inch (125 mm). 1/2 inch NPT female conections for air vent and drain
valve. Maximum working pressure 100 psi. Working temperature range 32 to 230 degrees F (0 to 110 degrees C). Suitable fluids: water
or 50 percent maximum glycol solution. Max. flow rate: 9 gpm (0.5 l/s) primary, 22 gpm (1.5 l/s) secondary (total all branches). Provided
with air vent and drain valve.
Code 559921A
HydroLink hydraulic separator plus distribution manifold header with built-in wall mounting, branches 2+1, for heating systems. Painted
seel body with pre-formed insulation. Main connections (to primary) 1 inch NPT female, center distance 2-3/8 inch (60 mm); connections
to branches (secondary) 1 inch NPT male, center distance 4-15/16 inch (125 mm). 1/2 inch NPT female conections for air vent and drain
valve. Maximum working pressure 100 psi. Working temperature range 32 to 230 degrees F (0 to 110 degrees C). Suitable fluids: water
or 50 percent maximum glycol solution. Max. flow rate: 9 gpm (0.5 l/s) primary, 22 gpm (1.5 l/s) secondary (total all branches). Provided
with air vent and drain valve.
Code 559922A
HydroLink hydraulic separator plus distribution manifold header complete with angle mounting brackets, branches 2+2, for heating
systems. Painted seel body with pre-formed insulation. Main connections (to primary) 1-1/4 inch NPT female, center distance 3-1/8 inch
(80 mm); connections to branches (secondary) 1 inch NPT male, center distance 4-15/16 inch (125 mm). 1/2 inch NPT female conections
for air vent and drain valve. Maximum working pressure 100 psi. Working temperature range 32 to 230 degrees F (0 to 110 degrees C).
Suitable fluids: water or 50 percent maximum glycol solution. Max. flow rate: 11 gpm (0.7 l/s) primary, 26 gpm (1.7 l/s) secondary (total
all branches). Provided with air vent and drain valve.
Code 559931A
HydroLink hydraulic separator plus distribution manifold header complete with angle mounting brackets, branches 3+1, for heating
systems. Painted seel body with pre-formed insulation. Main connections (to primary) 1-1/4 inch NPT female, center distance 3-1/8 inch
(80 mm); connections to branches (secondary) 1 inch NPT male, center distance 4-15/16 inch (125 mm). 1/2 inch NPT female conections
for air vent and drain valve. Maximum working pressure 100 psi. Working temperature range 32 to 230 degrees F (0 to 110 degrees C).
Suitable fluids: water or 50 percent maximum glycol solution. Max. flow rate: 11 gpm (0.7 l/s) primary, 26 gpm (1.7 l/s) secondary (total
all branches). Provided with air vent and drain valve.
RT
CALEFFI
CALEFFI
CALEFFI
10
0
8
6
4
2
10
0
8
6
4
2
CALEFFI
10
0
8
6
4
2
10
0
8
6
4
2
10
0
8
6
4
2
10
0
8
6
4
2
CALEFFI
CALEFFI
°C
0
20
80
60
40
CALEFFI
°C
0
20
80
60
40
20
25
30
35
40
45
50
55
60
RT
CALEFFI
CALEFFI
CALEFFI
10
0
8
6
4
2
10
0
8
6
4
2
CALEFFI
10
0
8
6
4
2
10
0
8
6
4
2
10
0
8
6
4
2
10
0
8
6
4
2
CALEFFI
CALEFFI
°C
0
20
80
60
40
CALEFFI
°C
0
20
80
60
40
20
25
30
35
40
45
50
55
60
System with
wall-mounted
boiler and
built-in mounting
HydroLink 2+1.