Product Overview
Hydronic separator-manifold
HydroLink
™
series 559
Function
The Hydrolink, a new device combining a hydronic separator and
distribution manifold, is used in heating and air-conditioning
systems to allow different heat adjustments of the various rooms
when there is only one boiler or chiller.
The various configurations are compact, and can be easily fitted in
any kind of hydronic circuit, with the advantages of ease of
installation and a saving of useful living space.
Patent application No. MI2001A001270
CALEFFI
Product range
Code 559022A External 2+2 separator-manifold. Complete with support brackets and pre-formed insulation Size 1 1/4”; branches 1”
Code 559031A External 3+1 separator-manifold. Complete with support brackets and pre-formed insulation Size 1 1/4”; branc hes 1”
”1sehcnarb;”1eziSnoitalusnidemrof-erphtiwetelpmoC.dlofinam-rotarapes1+2ni-tliuBA120955edoC
Technical characteristics
Body
leetsdetniaP:ydoB-:lairetaM
Medium: Water and non-hazardous glycol solutions
%05:elocylgfoegatnecrepxaM
)rab6(isp09:erusserpgnikrow.xaM
Te )C°011÷0(F°032ot23:egnarerutarepm
Connections: - main: 3+1 and 2+2: 1 1/4” F NPT
2+1: 1” F NPT
- branches: 3+1 and 2+2: 1” M NPT
2+1 (bottom): 1” M NPT
2+1 (side): 1” F NPT
- air vent valve: 3+1, 2+2 and 2+1: 1/2” F straight
- drain cock: 3+1, 2+2 and 2+1: 1/2” F straight
Center distances:
- main: 3+1 and 2+2: 3 1/8” (80 mm)
2+1: 2 3/8” (60 mm)
- branches: 3+1 and 2+2: 3 1/2” (90 mm)
2+1: 3 1/2” (90 mm)
Insulation
XEPdednapxellec-desolC:lairetaM
)mm02(”4/3:ssenkcihT
Density: - inner part: 2 lb/ft
3
(30 kg/m
3
)
- outer part: 3 lb/ft
3
(50 kg/m
3
)
Thermal conductivity: - at 32°F (0°C): 0.26 BTU/in (.038 W/mK)
- at 100°F (40°C): 0.31 BTU/in (.045 W/mK)
Vapor resistance coefficient (DIN 52615): > 1.300
Te )C°001÷0(F°212ot23:egnarerutarepm
Fire resistance (DIN 4102): Class 1 (Class B2)
Flow Characteristics
Maximum recommended flow rates at connections:
Branches Primary Secondary (total)
2+1 9 gpm (2.0 m
3
/h) 22 gpm (5 m
3
/h)
2+2 11 gpm (2.5 m
3
/h) 26 gpm (6 m
3
/h)
3+1 11 gpm (2.5 m
3
/h) 26 gpm (6 m
3
/h)
01084/05 NA
cert. n° 0003
ISO 9001