SCALD PROTECTION THERMOSTATIC MIXING VALVES FOR PLUMBING
5213
Scald Protection
Point-of-Use
ASSE 1070
Code Description Cv Lbs USD
521333A
3
/
8
" compression union 2 2 139.00
521347A ½" PEX crimp union 2 2 164.00
521348A ½" PEX expansion union 2 2 164.00
521342A ½" NPT male union 2 2 172.00
521349A ½" sweat union 2 2 164.00
521357A ¾" PEX crimp union 2 2 172.00
521358A ¾" PEX expansion union 2 2 172.00
521352A ¾" NPT male union 2 2 179.00
521359A ¾" sweat union 2 2 172.00
521367A 1" PEX crimp union 2 2 205.00
521368A 1" PEX expansion union 2 2 205.00
521362A 1" NPT male union 2 2 212.00
521369A 1" sweat union 2 2 205.00
521301A* Replacement body, no fittings 2 1.5 113.00
COLD
HOT
SinkMixer installation diagram
Adjustable thermostatic mixing valve for point of
use where protected from scalding caused by hot
water with locking set point. Complete with check
valves on both hot and cold inlets.
Low-lead brass body.
Max. working pressure: 150 psi.
Max. inlet temperature: 185ºF.
Adjustable range: 85—120ºF.
Temperature control: ±3°F.
Min. flow for optimum performance: 0.5 gpm.
Max flow for optimum performance 9 gpm.
Meets requirements of ANSI/NSF 372-2011. Certified to ASSE 1070, CSA B125.3, UPC, IPC, Low Lead Laws and listed by ICC-ES for use in accordance
with the U.S. and Canadian plumbing codes.
*See fitting selection table in Section 8.
Thermostatic mixing valve for under sink
and under counter applications where the
user must be protected from the danger of
scalding caused by hot water.
Temperature adjustment range: 95—120ºF.
Cold inlet temperature: Min. 39°F; Max. 85°F.
Hot inlet temperature: Min. 120°F; Max. 195°F.
Maximum operating differential pressure:
Static: 150 psi (10 bar).
Dynamic: 70 psi (5 bar).
Min. operating differential pressure (dynamic):
1.5 psi (0.1 bar).
Min flow for optimum performance 0.35 gpm.
Max flow for optimum performance 2.3 gpm.
5212
SinkMixer
TM
4-way
Scald Protection
Point-of-use
Code Description Cv Lbs USD
521201A
3
/
8
" compression union 0.52 1 100.00
Operating principle 5212 SinkMixer
TM
The thermostatic mixing valve mixes hot and cold water in such a way as
to maintain constant set temperature of the mixed water at the outlet. A
thermostatic element is fully immersed into the mixed water. This element
then contracts or expands causing movement of the piston, closing either
the hot or cold inlets, regulating the flow rates entering the valve. If there
are variations of temperature or pressure at the inlets, the internal element
automatically reacts to restore the original temperature setting. In the event
of a failure of either the hot or cold supply, the piston will shut off, stopping
water discharging from the mixed water outlet.
COLD INLET
HOT INLET
MIX OUTLET
COLD OUTLET
NEW
NEW
ASSE 1070
Thermal shutoff
In the event of a failure of the hot supply port, the piston closes the cold
supply port. Similarly, if the cold water supply fails, the piston closes the
hot supply port. The Caleffi 521201A thermostatic mixing valve requires a
minimum temperature differential from hot inlet to mixed water outlet of 18°F
(10°C) to ensure the correct operation of the thermal shutoff feature.