STORA&E TANKS
Storage tanks can serve as either a domestic hot water tank or a thermal
buffering tank with porcelain glass coated steel lining. Powder-coated steel
external cover. Drain port/valve.
Max. working pressure: 150 psi.
Working temperature: -40—190ºF.
Recommended max. delivery water temperature: 120ºF.
Testing pressure: 300 psi.
Tank insulation: 2" non-CFC foam.
Insulation thermal conductivity: R16.
Temperature & pressure relief valve: 210ºF/150 psi. (HX models)
Electric element: 4.5 Kw. UL listed.
Connections: 25 gal. no HX (6) 1½" NPT F top & side, (2) ¾" NPT F top & side.
Non HX (7) 2" NPT female side, (3) ¾" NPT female top.
50 gal. HX (2) 1" NPT male side, (2) ¾" NPT male on top.
80-119 gal. (1) HX (3) 1" NPT male side, (1) 1" NPT male top.
80-119 gal. (2) HX (5) 1" NPT male side, (1) 1" NPT male top.
NAS200
SolarCon™
Code Description Lbs USD
NA10234 2" NPT male x ¾" NPT female 0.4 49.80
Code Description Lbs USD
NA10093 1" NPT female x 1" male 0.5 64.60
Code Description Lbs USD
NA3140-02 ¾" SolarFlex with 1" union nuts 1 194.30
90º brass elbow to connect ¾" SolarFlex™
to heat exchanger in SolarCon tank.
Reducer bushing fi ts tanks without HX for
installing temperature probe.
Low lead brass
1 5/8" hex head.
Insulated 6’ SolarFlex™ for connecting
solar pump station to SolarCon™ HX.
STORA&E TANK ACCESSORIES
Code Description Lbs USD
NA10082 ¾" NPT male x ½" NPT female 0.3 8.00
No HX
Typical applications include where system design requires use of an external
heat exchanger, an open solar thermal system, or when buffering storage
capacity is required.
One HX
A coil type solar loop HX is located in the lower portion of the tank. An electri-
cal heating element provides boost heat for a one tank system, or is unused
for a two tank pre-heat system.
Two HX
Coil type HX’s are located in the lower and upper portions of the tank. Com-
mon applications include using the upper HX for boost heat when connected
to a back-up heat source, using the top HX for supplemental space heat, or
connecting both HX’s to the solar loop for layer loading.
Two HX with electrical element
Typical application is for a one tank domestic hot water system with electric
element boost, and utilizing upper HX for supplemental space heat.
tech. broch. 01175
Function
Code Description Lbs USD
NAS20025 25 gal. no HX 100 2,657.00
NAS20050 50 gal. no HX 200 3,176.00
NAS20053 50 gal. 1 HX , electric element 231 4,043.00
NAS20080 80 gal. no HX 250 3,754.00
NAS20083 80 gal. 1 HX, electric element 297 5,486.00
NAS20082 80 gal. 2 HX 327 6,064.00
NAS20120 119 gal. no HX 350 4,967.00
NAS20123 119 gal. 1 HX, electric element 397 6,526.00
NAS20122 119 gal. 2 HX 427 7,161.00
NAS20124 119 gal. 2 HX, electric element 429 7,392.00
Code Description Lbs USD
NA10229 ¾" NPT x 36" anode rod fi ts 50 gal. 8.0 64.10
NA10230 ¾" NPT x 40" anode fi ts 80 &120 gal. 9.0 71.40
Magnesium anode rod.
Code Description Lbs USD
NA10339 2" NPT male plug, stainless steel 0.2 43.40
*Reduction of Lead in Drinking Water Act Compliant: 0.25% max. weighted
average lead content. Certifi ed through Underwriters Laboratory (UL) in ac-
cordance with NSF/ANSI 372.
NEW
NEW
Male plug 1 1/4" square head.
Brass reducing bushing. 1
1
/
8
" hex head.
NEW