Brochure

80
6
C
PRESSURE REDUCING VALVES FOR PLUMBING
Construction details
bar
High performance piston type pressure
reducing valve for high rise buildings and
other applications where high pressures are
present and require staged pressure control.
The 536A series carries out the rst stage
pressure reduction in a two valve series
where the pressure ratio between the inlet
and outlet would be too high for a single
pressure reducing valve to control.
Max. working pressure: 360 psi.
Max. working temperature: 180°F.
Pressure setting range: 90 – 150 psi
Factory setting: 115 psi
536A
PresCal
HP
Code Description Max GPM Lbs USD
536043A 109 1/2" sweat 7 3.3
168.00
536053A 109 3/4" sweat 12 4.4 177.00
536063A 109 1" sweat 19 5 257.00
536073A 109 1-1/4" sweat 34 7.5 463.00
536083A 109 1-1/2" sweat 44 8.8 698.00
536093A 109 2" sweat 70 11.2 898.00
536043A 103 1/2" NPT female 7 3.3 176.00
536053A 103 3/4" NPT female 12 4.4 187.00
536063A 103 1" NPT female 19 5 271.00
536073A 103 1-1/4" NPT female 34 7.5 487.00
536083A 103 1-1/2" NPT female 44 8.8 735.00
536093A 103 2" NPT female 70 11.2 945.00
536053A 106 3/4" press 12 4.4 215.00
536063A 106 1" press 19 5 312.00
536073A 106 1-1/4" press 34 7.5 561.00
536083A 106 1-1/2" press 44 8.8 845.00
536093A 106 2" press 70 11.2 1,087.00
Application diagram
580 Series
1
st
stage
PRV
2
nd
stage
PRV
bar
bar
FROM BOOSTER
PUMP STATION
STORIES AT LOWER LEVELS
bar
CA
L
EF
FI
580 Series
bar
C
A
LEF
FI
580 Series
HOT WATER
PRODUCTION
bar
CALEF
FI
580 Series
bar
CALEF
F
I
580 Series
Large system with recirculation
Complies with NSF/ANSI 372, Drinking Water System Components-Lead Content Reduction
of Lead in Drinking Water Act, California Health and Safety Code 116875 S.3874, Reduction
in Drinking Water Act, Vermont Act 193 - The Lead in Plumbing Supplies Law and Maryland’s
Lead Free Law HB.372, as certied by ICC-ES, le PMG-1360.
NEW
NEW