Brochure

56
6
A
THERMOSTATIC MIXING VALVES FOR PLUMBING AND HYDRONICS
Meets requirements of NSF/ANSI 372-2011. Complies with ASSE 1017,
CSA B125.3, UPC, IPC, Low Lead Laws and listed by ICC-ES for use in
accordance with the U.S. and Canadian plumbing codes.
Body is DZR low lead brass.
Adjustment temperature range: 95ºF — 150ºF.
Max. body pressure rating (static): 150 psi.
Max. working pressure (dynamic): 75 psi.
Max. inlet temperature: 195°F.
Gauge scale: 30—210ºF.
Min/Max ow: 0.5 gpm minimum, 9 gpm.
maximum (1/2" and 3/4" valves); 1.0 gpm.
minimum, 16 gpm maximum (1" valves).
520
AngleMix
with
Code Description Cv Lbs USD
520419A ½" sweat union 2 1.7 200.00
520419AC ½" sweat union, checks 2 1.8 216.00
520410A ½" NPT male union 2 1.7 207.00
520410AC ½" NPT male union, checks 2 1.8 224.00
520416A ½" press union 2 1.8 210.00
520519A ¾" sweat union 2 2 215.00
520519AC ¾" sweat union, checks 2 2.1 239.00
520510A ¾" NPT male union 2 2 215.00
520510AC ¾" NPT male union, checks 2 2.1 258.00
520516A ¾" press union 2 2 207.00
520516AC ¾" press union, checks 2 2.1 258.00
520619A 1" sweat union 3.5 3.7 289.00
520619AC 1" sweat union, check valves 3.5 3.8 313.00
520610A 1" NPT male union 3.5 3.9 297.00
520610AC 1" NPT male union, check valves 3.5 4 321.00
520616A 1" press union 3.5 3.7 301.00
520616AC 1" press union, check valves 3.5 3.9 326.00
MIX
30
50
70
90
110
130
150
170
190
210
ºF
GAUGE
ANTI-SCALE
POLYMER
MATERIALS
COLD
MIX
HOT
EASY-GRIP
KNOB
TAMPER-PROOF
SETTING LOCK
LARGE MIXING
CHAMBER
Replacement body.
See tting selection table in Section 8.
520
AngleMix
Body
Code Description Cv Lbs USD
520051A 1" union body (½", ¾" valves) 2 2 129.00
520061A 1¼" union body (1" valves) 3.5 4 180.00
Application diagram
Construction details
Anti-scale materials The material used in the construction of the Calef
AngleMix 520 series thermostatic mixing valve reduces jamming caused
by lime deposits. All the working parts such as shutter, seats and slide
guides are made of a special anti-scale polymer material, with a low friction
coefcient, assuring long term performance.
Temperature setting and locking The control knob permits temperature
setting between minimum and maximum in one turn (360°). It also has a
tamper-proof system to lock the temperature at the set value.
Thermal shut-off In the event of accidental cold water supply failure,
the shutter seals off the hot water passage, thus preventing the delivery
of mixed temperature water. This is only guaranteed when there is a
minimum temperature difference between the inlet hot water and the mixed
temperature water delivery of 18° F. Additionally, the tight closing hot inlet
port prevents temperature creep in recirculation applications.
As a convenience, the codes with "AC" sufx are supplied complete with a
check valve in the hot and cold inlet ports.
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW
NEW