Getting Started For more information visit www.caldigit.
CalDigit VR2 RAID 1 PROTECTED Apple, Apple Logo, Mac, the Mac logo and Macintosh are trademarks of Apple Inc. Microsoft, Windows and Windows Logos are registered trademarks of the Microsoft Corporation. All other trademarks are the property of their respective owners. 02 *Specifications and package contents are subject to change without notice.
Contents Introduction 4 CalDigit VR2 Overview 8 Installing the CalDigit VR2 9 General Use Warnings Safety Warnings Tech Specs Package Contents CalDigit VR2 Front Panel CalDigit VR2 Rear Panel 5 5 6 7 8 8 LCD Menu Overview 10 RAID Tool Feature Overview 13 Configuring your RAID 15 Accessories and Parts 19 Technical Support & Warranty Information 20 LCD Display Information CalDigit VR2 LCD Menu Tree Overview Using the LCD Menu Using RAID Tool Technical Support CalDigit Warranty Information
Introduction Thank you for choosing the CalDigit VR2. The CalDigit VR2 is the most complete two drive RAID system on the market today. It offers unmatched performance, impressive connectivity and superior quality all in a sleek and easily upgradeable enclosure that is both portable and functional. Please use the following quick installation instructions to setup your CalDigit VR2. Note: Please only use the CalDigit VR2 in places with cool and natural ventilation.
General Use Warnings Please read the CalDigit VR2 manual thoroughly and become familiar with the product before use. Only use the CalDigit VR2 in an area with cool ventilation. Make sure that the fan is not obstructed to ensure heat dissipation. Do not leave or use the VR2 near a heat source such as a heater or direct sunlight. Avoid using the VR2 in extremely hot and cold environments as it will increase the likelihood of premature drive failure. A safe temperature range is between 40F – 95F.
Tech Specs Tech Specs Size and Weight: Height: 3.6 inches (92 mm) Width: 5.3 inches (134 mm) Depth: 8.5 inches (216 mm) Weight: 6.6lbs (3.0 kgs) Interface and Data Transfer: 1x SuperSpeed USB 3.0 Port up to 5Gbps 1x eSATA Port up to 3Gbps 2x FireWire 800 (IEEE 1394b) Ports up to 800Mbps 1x FireWire 400 (IEEE 1394a) Port up to 400Mbps RAID Function: Supports RAID 0, 1, Spanning, JBOD* Automatic online fast disk rebuilding Automatic disk failure detection Hot swappable disks *USB 3.
Package Contents: 1. (One) CalDigit VR2 2. (Two) CalDigit drive modules 3. (One) FireWire 800 cable 4. (One) eSATA cable 5. (Two) drive module keys 6. CalDigit Driver & Manual CD 7. (One) Power supply kit Please contact your CalDigit reseller for any faulty or missing parts. DWARRA NDE NTY EXTE EXTE NTY DWARRA E D N Congratulations on your purchase of this CalDigit product! To make the most of your storage investment you can purchase the CalDigit Extended Warranty.
CalDigit VR2 Overview CalDigit VR2 Front Panel LCD Screen CalDigit VR2 RAID 1 PROTECTED Left Button Right Button LED Status Lights Ventilation Holes Smart Fan Power Button CalDigit VR2 Rear Panel Drive Key Hole Drive Module A0 Drive Module A1 Power Security Lock* eSATA USB 3.0 FireWire *Security lock (lock is not included) Use a standard computer lock to secure the CalDigit VR2 and prevent theft.
Installing the CalDigit VR2 The CalDigit VR2 is ready to use out of the box. 1 Select the desired interface, FireWire 400, FireWire 800, USB 3.0 or eSATA. A FireWire 800 and eSATA cable are included. 2 Connect the power supply to the CalDigit VR2, then connect the desired interface cable. 3 Press the CalDigit VR2's power button. The CalDigit VR2 will boot. You should see the CalDigit VR2 mount and it's ready to use.
LCD Menu Overview LCD Display Information The CalDigit VR2 LCD displays information in the following order: 1 System Profile - will display the status of 8 features 1.1 RAID status Displays the current RAID status. 1.2 Serial number Displays the CalDigit VR2 serial number. 1.3 Firmware version Current CalDigit VR2 firmware version. 1.4 System temp Displays the current system temperature. 1.5 Disk 1 temp Displays temperature of the top hard drive. 1.
3 MISC config - internal system set up 3.1 Beeper on/off Turn the audible alarm on or off. 3.2 Turbo Mode on/off Turn Turbo Mode on or off. Turbo Mode is designed to provide the CalDigit VR2 with an extra speed boost. 3.3 Japanese language Toggle the CalDigit VR2 LCD menu between English or Japanese. 3.4 Boot option 1/2 Toggle between boot option 1 or 2. Boot option is recommended for most users, who are using the CalDigit VR2 as a boot drive under OS X.
CalDigit VR2 Menu Tree Overview CalDigit Menu ● SYSTEM PROFILE ● CREATE RAID STATUS CREATE RAID 0 BEEPER ON/OFF SERIAL NUMBER CREATE RAID 1 TURBO MODE ON/OFF FIRMWARE VERSION CREATE SPAN JAPANESE LANGUAGE SYSTEM TEMP CREATE JBOD BOOT OPTION 1/2 DISK1 TEMP CLEAR RAID INFO ACCESS LED ON/OFF DISK2 TEMP AUTO REBUILD ON/OFF "BEEPER STATUS LOAD DEFAULT CFG LCD CONFIG STATUS" "ACCESS LED STATUS AUTO REBUILD STATUS" ● ARE YOU SURE? ● ERASE ALL DATA ● FINAL CONFIRM 12 ● MISC.
RAID Tool Feature Overview RAID Tool provides several types of display information to help users obtain the current status of the CalDigit VR2. 1 RAID information Provides related information for the current RAID set. 2 RAID configuration Create RAID 0, RAID 1, JBOD or SPAN. 3 Email configuration Error logging system set up. When an error occurs, the CalDigit VR2 will automatically send out the log to the system administrator via email. Internet connection required.
4 Fan and Temperature Obtain current environmental data for the CalDigit VR2. 5 Event Log Displays log of all CalDigit VR2 events. 6 Firmware update Manually update the CalDigit VR2 Firmware, to add new features or bug fixes. 7 MISC. Configuration Set RAID Tool password protection, LCD config enable/disable, beeper enable/disable and VR2 nickname to customize LCD with personalized message. 8 Re-Scan Re-Scan all devices connected to the computer.
Configuring your RAID If you wish to create your RAID from the LCD, please follow the steps below. 1 Turn on the CalDigit VR2. Press the right button next to the LCD panel. Press the button one more time when the LCD displays Create RAID. Confirm by pressing the left button. 2 You will see the CalDigit VR2 cycle through the following RAID levels; RAID 0>RAID 1>SPAN>JBOD>Clear RAID Info. Select the desired RAID level by pressing the right button.
5 Please wait a moment while the CalDigit VR2 creates the RAID. 6 The CalDigit VR2 will restart automatically. 7 Please restart your computer. 8 The CalDigit VR2 will display the new RAID setting. It can be verified via RAID Tool or the LCD. 9 Once the computer has restarted a message will appear asking you to initialize your CalDigit VR2. • Disk Utility will launch and allow you to format the CalDigit VR2.
If you wish to create your RAID using RAID Tool, please follow the steps below. 1 Launch RAID Tool. RAID Tool can be found in the Applications > CalDigit RAID Tool folder. 2 2. Select the desired CalDigit VR2 to enter the menu. 3 Select RAID configuration. Note: the bottom of the RAID Tool will show you different RAID configurations. 4 Choose the desired RAID level and click "Yes" to proceed. Press "No" to cancel. WARNING: Changing RAID level will cause all data on the array to be lost.
6 Check LCD and RAID Tool to make sure that the RAID levels match. 7 Please restart your computer. 8 Run Disk Utility (Mac) or Disk management tool (PC) to format your CalDigit VR2. 9 Once the computer has restarted a message will appear asking you to initialize your CalDigit VR2. • Disk Utility will launch and allow you to format the CalDigit VR2. If you do not see this message, simply launch Disk Utility which can be found in the Applications > Utilities folder. • Select the erase tab.
Accessories and Parts SuperSpeed PCI Express Card for USB 3.0 for Mac Part # U3-HostAdapter SKU # 791900 SuperSpeed ExpressCard for Laptop Part # U3-ExpressCard SKU # 791901 CalDigit FireWire 800 cable, 9-pin to 9-pin, 6ft Part # CBFWY9-6 SKU # 704102 CalDigit USB 3.0 A/B Cable, 3ft Part # CBUSB3AB-3-CD SKU # 791980 CalDigit USB 3.0 A/B Cable, 6ft Part # CBUSB3AB-6-CD SKU # 791981 CalDigit VR Power Supply Part # CDPS-0512 SKU # 704101 2 port PCI-e SATA 6G & 2 port USB 3.
Technical Support & Warranty Information Technical Support If you run into any issues while installing your CalDigit VR2 please contact CalDigit Technical Support: support@caldigit.com www.caldigit.com/support.
CalDigit VR2 Manual v1.0 www.caldigit.com © 2012 CalDigit, Inc.