User Guide
40 — PiPe Trades Pro™
Combination Rolling Offset
Unlike a regular rolling offset, the entry and exit ttings for a 
combination rolling offset are on different planes and therefore 
have different tting angles from each other.
Horizontal to Vertical
Find the pipe length, and entry and exit tting angles for a 
combination rolling offset with a vertical pipe exit, given a 
Roll of 23”, Offset of 15”, and Advance of 29”. Use the box in 
Diagram 1 to review the entry and exit pipe perspectives.
0’ -29”
ADVANCE
0’ - 15”
Offset
0’ - 23”
Roll
Unknown
Entry Fitting
Angle
Diagram 1
KEYSTROKE  DISPLAY
    ALL CLEArEd
1. Solve for the pipe length and entry tting angle
       OFST 15 INCH
      (Advance)  RUN 29 INCH
        (Roll)  LNTH 39-15/16 INCH
   FIT° 43.44°
Do not clear or reset the calculator.
If the box is oriented in a 2-dimensional perspective (Diagram 2), 