User manual
CONFIGURATION
001-7100-100 Version 0 Page 48 of 66 Vanguard 3G User Manual CDMA Version
5.7.4 Advanced Settings-Remote Admin and Power Management
Figure 30 - Remote Admin
5.7.4.1 Remote Admin
Remote Configure: Selecting Enable will allow remote access to the modem’s configuration
screens through the cellular network connection. Selecting Disable will shut off the ability to
remotely access the modem’s configuration screens.
Incoming Port: Change the port of incoming requests. It is not necessary to change this
parameter unless it conflicts with other devices on the network.
Admin Password: Set the password for BOTH remote login and local login. The password
must be entered twice for the password to change.
Note:
Changing any remote administration parameters remotely will cause the remote user to
lose contact with the Vanguard 3G unit. Login using new parameters to re-establish a
connection.
IMPORTANT NOTE:
Users can be logged into a single unit both locally and remotely at the same time.
Changes made on one end will not be reflected on the other unless the web page is
refreshed.
5.7.4.1.1 Example of Remote Login
The following should be entered into a browser on a remote PC to remote login to the Vanguard 3G
radio modem. The Vanguard 3G unit must have remote administration enabled for this functionality
to work.
Note: “HTTP” must be
specified or browser will
assume other uses
http://70.209.115.93:8080
“PPP IP Address”
“Incoming Port”
On home page
On LAN Settings Page
Figure 31 - IP Address Definitions