User manual
Reverse Power
Reverse power in watts or dBm.
External I/O 1
Voltage on the External I/O 1 Input from the Power - I/O Connector (in volts).
External I/O 2
Voltage on the External I/O Input from the Power - I/O Connector (in volts).
Preamble Good
The number of correctly decoded transmissions received in the last 15. Used with Preamble Total, this serves as an
indication of how well the unit is receiving data.
Preamble Total
The number of total transmissions detected, maximum is 15. Used with Preamble Good, this serves as an
indication of how well the unit is receiving data.
RSSI/Pwr
This panel shows the current RSSI level (in dBm) while the local unit is receiving and the current power level (in
watts or dBm) while the local unit is transmitting.
Rev Pwr
This check box changes forward power to reverse power on the Power Panel from while the local unit is
transmitting.
Power in dBm
This check box allows the user to view Fwd/Rev Power in dBm (instead of watts).
Tx Mode
This box allows the user to select different transmit modes when the unit is told to transmit.
• Tone - the unit transmits a 1200 Hz tone
• Mod Balance - the unit transmits a 100 Hz square wave
• Random Data - the unit transmits random data
• No Modulation - the unit transmits a carrier with no modulation
Rx/Tx Frequency
Shows the current transmit frequencies
F5
Pressing the F5 key will cause the unit to transmit on the programmed transmit frequency
F6
Pressing the F6 key will cause the unit to go to receive on the programmed receive frequency