Rebooting the unit would lose all neighbor entries and the detection process would have to be re-started.
Enabling the Autolock feature allows preserving acquired information in the unit’s flash memory.
When rebooting with Autolock enabled, the neighbor discovery module assumes the neighbor table is
complete (It does not try to detect the presence of other units). When adding another unit to the network,
it will try to detect all its neighbors, and by doing so, it will be detected by the current unit and added to
its neighbor table.
This new entry will be saved in the unit’s flash memory after the convergence timeout has expired.
6.7.7.1 Local Info
Figure 81 - Local Info
Item Description
RF IP Address Displays unit's RF IP address and netmask .
Ethernet IP Address Displays unit's Ethernet IP address and netmask.
Status
Displays the unit's status:
Unit's Operating mode: Master, Repeater or Remote
Relay Point (RP) if enabled
NAT if enabled
Access Point (AP) if enabled
Proxy if TCP is enabled
Locked if all dynamic neighbor table entries are locked
Lock/Unlock
Manually locks (or unlocks) the unit’s Neighbor Table.
When locked, all neighbor table entries will be saved in the unit’s Flash
memory. Their status will be changed to static. A unit in a locked state
will not perform neighbor discovery at start up. It will assume the
neighbor table complete. If another unit is added to the network, it will
try to detect all its neighbors and by doing so it will be detected by the
current unit and added to the neighbor table. However, the new table
entry’s status will be kept as dynamic.
6.7.7.2 Neighbor Table
Each unit has a Neighbor Table. This table has an entry for each neighboring unit detected in the RF net-
work.