User manual

001-5099-000 HiPR-900 User Manual
60
The following setup example would allow the “Sender” unit to communicate with different multicast
groups. The settings shown in Figure 61 below, and Figure 62, would enable the Sender unit to reach all
entities of the various groups. Figure 61 illustrates setup on the Master unit.
Figure 61 - Multicast Window Details (On the Main HiPR-900 unit)
Multicast (Enabled/Disabled)
Enables or disables the registration of the multicast groups by the main HiPR-900
unit.
Outbound unit address Indicates the “All Remote HiPR-900 unit” multicast group
Multicast Address List Indicates the various “Remote Host” groups
Figure 62 - Registration to multicast group
Sender
Network
“All Remote HiPR-
900” group
(224.168.201.1)
Master HiPR-900 uni
t
RF Airlinks
Remote Host
Remote Host
Remote Host Remote Host
Remote Host
“Remote Host” group 1
(224.168.200.1)
“Remote Host” group 2
(224.168.200.2)
Remote 1 Remote 2 Remote 3
Remote 4
Remote 5