User manual

001-5099-000 HiPR-900 User Manual
41
6.7.3 Setup (Advanced)
6.7.3.1 LAN (IP)
Figure 37 - Advanced IP Configuration - LAN (IP)
Item Description
MTU
Ethernet Interface MTU - Default 1500 bytes. - Entering a value lower than 1500 may
reduce system performance. Range is 576 to 1500.
MAC address Ethernet Interface MAC address in HEX format (factory-set).
Default IP Gateway Con-
trol
Disabled (Default), Enabled – Selects the unit that serves as the gateway between the
HiPR-900 units network and the outside network (management network). This unit is
also called the Access Point unit.
6.7.3.1.1 Access Point (Default Gateway)
When all units of a network are operating in router mode, the user can select one (and only one) of the
units to be the Access Point (the default gateway). This unit is considered the gateway to the management
network. All units will set their default route to point towards the access point unit. This is useful in some
settings where an internal host/device needs to access external networks that are not immediately con-
nected to any one of the units on the network. Each unit knows how to reach any other unit on the internal
network, but if a packet is sent to an outside (external) network, by default the packet is sent towards the
Access Point Unit.