001-5099-000 HiPR-900 User Manual
35
Item Description
Enabled Independent check boxes to activate SETUP PORT and/or DATA/COM PORT
Speed
Select 300, 1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200 Baud Rate
Default is 115200 for SETUP port and 9600 for COM port
Data Bits
Number of bits making up the data word. Set according to Host configuration. Default is
8.
Stop Bits Mark the end of the serial port data type. Default is 1.
Parity Added to identify the sum of bits as odd or even. Default is None.
Flow Control Select None or CTS-based (RTU dependent)
Connection Control Select Permanent (3-wire) or Switched (DTR bringup/teardown) (RTU dependent)
IP Gateway Service
Select one of:
CLI Service (Command line interface)- RS-232 connection to Host PC
Access to the Command Line Interface command shell is password protected and is
reserved to authorized Dataradio maintenance personnel.
Serial/RF bridge – IP Gateway service using UDP transport protocol (baud rate = 9600)
Diagnostics – TCP/IP based RF diagnostics
Custom – Choosing Custom enables the IP Gateway Transport configuration
Default is CLI Service for SETUP port and Serial/RF bridge for COM port.
IP Gateway Transport
Available only if IP Gateway Service selection is Custom, choose the socket connection
mode from the drop-down list box choices of TCP Server, TCP Client, or UDP.
Local IP Address
Valid unicast or multicast IP address, including the local Loopback interface address.
Default local IP address is set to 0.0.0.0 and can be changed dynamically without a unit
reset.
Local IP Port
For TCP Client and UDP socket connections, set to any value between 1 and 65535.
For TCP Server socket connections, set to any value between 1 and 65535 but must not
be set to one of the following values or fall within the following ranges of values: 20, 21,
23, 123, 520, 5002, 6254 to 6299, 7000 to 7100. Otherwise, the parameter configuration
will be accepted, but no socket connection will be established to accept connection
from remote endpoints.
Default local port value for SETUP port is set to 1024 and can be changed dynamically
without a unit reset.
Remote IP Address
Default remote IP address is the Loopback interface address, 127.0.0.1 and can be
changed dynamically without a unit reset
Remote IP Port
For all socket connection modes (TCP passive, TCP active, UDP), set to any value be-
tween 1 and 65535.
Default local port value for SETUP port is 23 and can be changed dynamically.