User manual
001-5099-000 HiPR-900 User Manual
14
sion) allows for the use of the Parallel decode technology, increasing receive capability by having a high-
er gain receive antenna separate from the rule-limited transmit antenna.
PoE allows for powering the HiPR-900 via the Ethernet port. A PoE power injector is required (DRL part
number 250-5099-001). The switch or hub allows for a local Ethernet connection by the user’s PC for the
purpose of set-up, troubleshooting and diagnostics and avoids the need to disconnect Ethernet RTU or
PLC. The two serial ports of the HiPR-900 can be setup to allow connections to legacy equipment such as
serial RTUs and PLCs.
5.4 Selectable Data Rates
Switchable data rates of 256 or 512 Kbps allow optimizing installations for highest throughput or maxi-
mum range. The sophisticated DSP modem gives optimal performance in either mode, whether a short-
range LAN extension or long-range link.
Figure 8 - Setup using Switch (or Hub) and PoE power injector
TX/RX
Antenna
PoE
PD(RX)
Antenna
User’s Serial
RTU or PLC #2
User’s Serial
RTU or PLC #1
User’s Ethernet
RTU or PLC #1
RJ-45
DAT
A
RJ-45
PWR &DAT
A
Switch or
Hub
Power Supply
+7 (495) 220-95-14 info@dataradio.ru www.dataradio.ru