User manual

001-5099-000 HiPR-900 User Manual
9
3.1 LEDS
HiPR-900 has five dual-color LED indicators. Their functions are shown in Table 3.
Table 3 - HiPR-900 LEDs indications
LED Color Definition
ACT Green Data transmission or reception activity – Off if no activity
LINK
Green Connection OK, no collision
Amber Connection OK, with collision
Tx / Rx
Green Data reception activity
Amber Data transmission activity
Red Receive CRC error or incomplete packet
SYNC
Green
Remote/Repeater: In sync with Master
Master: Normal
Red
Remote/Repeater: Loss of Master sync
Steady red = Master failure
PWR
Green
Steady green = Normal
Flashing green = Driver error
Amber (at boot-up) Normal (approx 5 secs)
Amber Application failure
Red
Steady red = Hardware failure
Flashing red = Power ON Self-test hardware error detection*
* Unit will reset (similar to power input recycling) 5 minutes after self-test hardware error is
detected (only done at Power ON).
Note:
Power LED steadily lit red or flashing red will require factory repair. Power LED flashing green will
require factory repair only if the unit is unable to transport traffic. Refer to section 1.4.1, RMA
REQUEST for mandatory factory repair procedure.
3.2 User Connector Pin-outs
3.2.1 Ethernet LAN Port
Table 4 - Pin-out for IEEE-802.3af RJ-45 receptacle contacts
Contact 10/100Base-T signal
1 TXP
(
1
)
2 TXN
(
1
)
3 RXP
(
1
)
4 SPARE +
5 SPARE +
6 RXN
(
1
)
7 SPARE -
8 SPARE -
SHELL Shield
(1) The name shows the default function. Given the auto-MDIX capability of the Ethernet transceiver,
TX and RX function could be swapped.
Note:
The HiPR-900 unit accepts PoE over the cable spare conductors and/or Data baring conductors as
follows:
Spare conductors: pins [4,5] as (+) or (-), pins [7,8] as the other polarity
Data baring conductors: in common mode, pins [1,2] as (+) or (-), pins [3,6] as the other polarity
+7 (495) 220-95-14 info@dataradio.ru www.dataradio.ru