User manual
001-5099-000 HiPR-900 User Manual
89
No overhead is generated in the HiPR-900 unit if no online diagnostic connection is actually
made.
Sample output for bridge mode (no IP address available)
[00:00:03:09], 0, 9, 100, 1, 5, 38, -51, -70, -108, 1000, 200
[00:00:03:09], 0, 9, 100, 1, 5, 38, -51, -70, -111, 1000, 200
Sample output for router mode
[192.168.36.188], 0, 9, 10, 0, 127, 46, -42, -70, -107, 1000, 200
[192.168.36.204], 0, 9, 10, 0, 103, 42, -53, -70, -110, 1000, 200
Decoding the last line (see Table 10): unit is 192.168.36.204 IP address (in router mode), type of report 0,
there are 9 fields to follow, 1/10 sampled packets are output, DC input is used, Volts are 10.3, Internal
temperature is 42°C, PER of 10
-5.3
, with a carrier level of -70 dBm signal, an average background level of
-110dBm, a forward power of 1000 milliwatts (1.0 watt), and a reverse power of 200 milliwatts (0.2
watt). old
Table 10 - Decoding Sample Output for Router Mode
Field
#
Field Name Sample Output Sample Output
Decoded
1 Source IP address
[192.168.36.204]
Unit’s IP address is
192.168.36.204
2 Report Type
0
0
3 Number of Fields to Follow
9
9
4
Number of data packets before a diagnostic
message is delivered
10
1/10 packets re-
ceived will generate
a diagnostic mes-
sage
5 Flags
0
DC input
6 Voltage Level
103
10.3 V
7 Internal Temperature
42
42°C
8 PER
-53
10
-5.3
9 Signal RSSI
-70
-70 dBm
10 Background RSSI
-110
-110 dBm
11 Forward power
1000
1000 mW (1.0 Watt)
12 Reverse power
200
200 mW (0.2 Watt)
+7 (495) 220-95-14 info@dataradio.ru www.dataradio.ru