User manual

120 20131-301 Gemini G3 - User Manual
62
5. Maintenance, Trouble-Shooting and Testing
The checks described below should be done at annual intervals or whenever deterioration in performance
is noted.
5.1 Equipment Required
13.8 VDC (nominal) car battery, or
13.8 VDC/20A regulated power supply (In the case the unit is not installed in a vehicle)
In-line watt meter (50W range and 10W range)
Radio service monitor (IFR-COM120B/C or equivalent).
Cable with male connector (check type of connection present on unit) to connect G3 radiomodem
to the service monitor.
5.2 Basic Tests
Recommended checks:
For checks 1 to 6, refer to Table 5 - Test Checklist next page.
1. Power-up LED Sequence
2. Transm
it power output
3. Reflected power output
4. Carrier frequency
error
5. TX Deviation
6. Main RX and Aux. RX RSSI
7. RF Link test between Paragon3 unit(s) and mobile unit (PING test from the unit’s Web page as per
paragraph 4.7.7.1 or PING from a PC as per paragraph 5.4.1)
8. GPS test as per 5.3.2.
Important note: Before proceeding make sure that the
service monitor has been recently calibrated and
has warmed up for at least the time specified by its manufacturer.
Some reported frequency and deviation problems have
actually been erroneous indications from service
monitors that have not adequately warmed up. This is particularly likely when field service is done during
winter months