6.6 Unit Status
6.6.1 Unit Status General
Displays values that identify the unit and show its basic operating condition.
Figure 14 - Unit Identification and Status
Item Description
Banner
Displays Paragon4 software revision information retrieved from the connected unit. Have
this information handy if contacting Dataradio support.
Station Name
Displays name of connected unit.
Configured under Setup Basic Î General Î Station Name
System ID
Displays System’s unique identification number
Configured under Setup Basic Î General Î System ID
Local Time
24-hour clock format display of the GMT time and date adjusted to the specified time zone.
Configured under Setup Advanced Î Time Source Î SNTP
CWID Callsign
Continuous wave ID - Way of sending FCC license ID using Morse code.
Continuous Wave Identification uses Morse Code to automatically send out the station ID
periodically to identify the owner of the transmitting base station. This satisfies the require-
ments of the FCC.
CWID Interval
Interval between CWID messages in minutes.
Zero = never.
Unit Status
Normally displays “Ok” in the message area.
Displays various warnings or messages in the event of hardware failure,
If indications persist, have the status information handy if contacting Dataradio support.
Host Status
Status of the link to the specified Host, if configured in Setup (Advanced) Roaming
Host Link Active.
Values displayed are Disabled, Reachable, and Unreachable.
Acknowledge Unit Status Press this button to clear the Unit Status message area.