User's Manual
001-2019-500 Rev 0 Paragon4 – UHF, 700 & 800MHz User Manual
96
8. Specifications
GENERAL UHF 700MHz 800MHz
Frequency Range (MHz)
FCC = 406.1 - 512 Rx/Tx
IC = 406.1 - 430 Rx/Tx
IC = 450 - 470 Rx/Tx
FCC = 757 - 758, 763 - 775 Tx
FCC = 787 - 788, 793 - 805 Rx
IC = 764 - 776 Tx
IC = 794 - 806 Rx
FCC = 851 - 869 Tx
FCC = 806 - 824 Rx
IC = 851 - 869 Tx
IC = 806 - 824 Rx
FCC Part 90 & 27 / IC RSS-119
Channel Spacing
12.5 / 25 KHz 12.5 / 25 / 50 KHz NPSPAC / 25 KHz
Mode of Operation
Full Duplex, 100% duty cycle
Cabinet Size
22.06” W x 75.82” H (without leveling feet) x 27.06” D
RF/Modem Assembly Size
(Rackmount) 19.0” W x 8.75” H x 12.5” D + 2.0” connector allowance
AC/DC Power Supply Assembly Size (Rackmount): 19.0” W x 3.5”H x 16.5” D
Power Amplifier Assembly Size (Rackmount): 19.0” W x 7”H x 6” D
Frequency Stability
1.0 ppm (-30°C to +60°C)
Supply Voltage
120 VAC / 6A max, 60 Hz to 13.8 VDC or
13.8 VDC nominal, negative ground (12.6 to 14.6 VDC range)
Circuit protection
Radio backplane: Main fuse (F1) 10A Blade fuse &
crowbar diodes for reverse polarity protection
Power Amplifier: Fuse protected, overvoltage protected & current limited via AC/DC power
supply or PA power cable with in-line 30A fuse for DC power supply application
RX Current Consumption @ 13.8 VDC
3.0A max. (Two receivers with speaker monitoring)
TX Current Consumption @ 13.8 VDC
24A DC typical @ 25C, 450
MHz & 100W
(26.5A DC max for -30 to
+60C, 403-512MHz & 100W)
22A DC typical @ 25C,
770MHz & 70W
(25A DC max for -30 to +60C,
757-775MHz & 70W
23A DC typical @ 25C,
860MHz & 70W
(26A DC max for -30 to
+60C, 851-869MHz & 70W
Operating Temperature Range
-30°C to +60°C (deleted power supply, catalog number with 0 in second to last digit)
-30°C to +50°C (with standard Heavy Duty Power Supply, catalog number with 2 in second to
last digit)
Modem / Network
User Interface
• Dual Ethernet RJ45 Auto MDIX 10-100/T with LED status indicators
• Dual RS-232 DB-9F Serial Ports configured as Terminal Servers
• USB Port (future use)
Addressability
Native TCP/IP and built-in router
Data Encryption
AES 128-bit
Protocols
• Dataradio Proprietary E-DBA with OOB AAVL support
• Ethernet IEEE 802.3, (ICMP, IGMP, TCP, UDP)
• IP Fragmentation, Address Resolution Protocol (ARP)
• IP directed broadcast, IP limited broadcast, IP multicast relay
• DHCP client and server
• Network Address Translation (NAT), Dynamic Routing (RIPv2)
Data rates
12.5 kHz ch.: 25 kHz ch.: 50 kHz ch.: NPSPAC ch.:
32 kbps
24 kbps
16 kbps
64 kbps
48 kbps
43.2kbps
32 Kbps
128 kbps
96 kbps
64 Kbps
32 kbps
24 kbps
16 kbps
Preliminary