counts the number of packets it receives successfully. The test results can be viewed on the
receiving Viper.
st mode, it will not respond to RF activity from
other Viper units. Test mode cannot be enabled (active) for more than 15
Warning: When the unit is in te
minutes. After 15 minutes, test mode will be automatically disabled and normal
communications will resume.
Figure 10.4 - Maintenance
D
Net Tests Web Page
0.4.1 Net Test Setup
on RF MAC address
The user enters the RF MAC address of the Viper unit they wish to connect to. Format
0x00000FD4. The default RF MAC address is 0xFFFFFFFF, which will send a broadcast
packet to all Vipers listening for the test packets.
Number of packets to transmit
This is the total number of packets transmitted during the test.
Delay between packets
The user can enter a delay in milliseconds between the packets being sent. Note: If a delay
is not prese ey and is only
ending one long continuous packet.
ttern
hat
1
Destinati
nt between packets, it may appear the transmitter does not unk
s
Packet data pa
The user can choose between a Fixed or Random data pattern. Fixed data is highly
compressible; random data is not. Note: The Viper has a data compression algorithm t
compresses the data before transmitting it.