User's Manual
#9 ViPR User Manual_Rev2.doc Page 26
Figure 3.4 PC LAN Setup
STEP 3: Select Use the Following IP Address and enter the following values:
IP Address: 192.168.205.254
Subnet Mask: 255.255.255.0
Default Gateway: (leave empty)
Figure 3.5 PC LAN Setup: Step 3
STEP 4: Click OK to apply your changes and complete the connection process. Some
Operating systems may require a reboot to complete the connection process.
MEASURE AND CONNECT PRIMARY POWER
Primary power for the ViPR must be within 10-30 VDC and be capable of providing a
minimum of 10 watt supply for Tx @ 1W, 40 watt supply for Tx @ 5W, or 60 watt supply for
Tx @ 10 W. (In ViPR Demo Kits, a power connector with screw-terminals is provided with