Modemoperatingparametersinclude:
LongID
TheelectronicIDNumberisauniquenumberassignedatthefactory.Thisnumbermaybechangedinthecaseofa
duplication.TheIDNumberisusedbytheprogrammerforremoteaddressinganddiagnostics.
Therangeofthisfieldis1to4294967295butmultiplesof1024shouldnot
beused.Amultipleof1024resultsina
ShortIDof0.IftheIDNumberiswithintherangeof1to1023,theShortIDwillbethesame.
NOTE:ThisIDisnotthesameastheprintedserialnumber.Usetheprintedserialnumberto
verifyiftheunitis
underwarranty.
ShortID
TheShortIDisderivedfromthelongerIDNumber.Itisusedtoidentifyunitsandminimizesthetimerequiredto
transmitOnlineDiagnostics.TheShortIDofeachunitinanetworkmustbeuniqueifOnlineor
OfflineDiagnosticswillbeused.SincetheShortIDisderived
fromtheIDNumber,noentryisallowedinthisfield.
TherangeoftheShortIDis1to1023.
Comment
TheCommentfieldcanbeusedasanotepad(i.e.,customername,location,technicalinfo...etccanbeenteredin
thisfield).Commentsaretextupto39charactersincludingspaces.
DateLastConfigured
TheDateLastConfiguredfieldshowsthedatetheunitwaslastprogrammed.Thedateistakenfromtheoperating
program.Noentryisallowedinthisfield.
TotalConfigurations
TheTotalConfigurationsfieldshowsthenumberoftimesaunithasbeenprogrammed.Noentryisallowedinthis
field.
OnlineDiagnostics
Ifenabled,diagnosticsinformationissentatthebeginningofeachtransmission.Diagnosticsinformationis
invisibletouserdataexceptfortheincreaseinRTS/CTSdelayof11ms(at9600b/s).Thedefaultvalueis“Enabled”
(checked).
Allunitsinanetworkmustusethesamesetting.Diagnosticsfromthelast
15stationsheardarestoredineach
unit.ThesevaluesarereadusingtheOfflineorOnlineDiagnosticsscreen.
Transmittedinformationincludes:
• ShortID
• SupplyVoltage(inVolts)