User's Manual

Integra-TR User Manual Page | 61
Minimum Time displays the minimum amount of time taken for the Ping Packet to echo back from the Remote
device (in milliseconds).
Maximum Time
Maximum Time displays the maximum amount of time taken for the Ping Packet to echo back from the Remote device (in
milliseconds).
Average Time
Average Time displays the average amount of time taken for the Ping Packet to echo back from the Remote device
(in milliseconds).
Blocks Tx’ed to Remote
Blocks Tx’ed to Remote displays the number of data packets sent to the Remote device.
Blocks Rx’ed from Remote
Blocks Rx’ed from Remote displays the number of data packets received from the Remote device.
Ping Quality
Ping Quality displays the overall percentage of data packets sent vs. data packets received during the Ping Test.
Type of Data
Type of Data displays the type of Data Pattern to be used for each packet. The size for each Data Pattern is shown below in
Packet Size. The following lists the formats of the Data Patterns:
ASCII Pattern
The packets will be 52 characters in length. The pattern used to build the packets will have the following format (in
ASCII):
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
---
ABCDEFGHIJKLMNOPQRSTUVWXYZabcdefghijklmnopqrstuvwxyz
ASCII Number Pattern
The packets will be 48 characters in length. The pattern used to build the packets will have the following format (in
ASCII):
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
---
00 11 22 33 44 55 66 77 88 99 AA BB CC DD EE FF
Binary Pattern