User's Manual
FEATURES AND OPERATION
2-2
Part No. 001-4090-101/102
2.2.3 SAFETY NOTICE
The Integra-H uses low power radio frequency transmitters. The concentrated energy
from an antenna may pose a health hazard. People should not be in front of the antenna
when the transmitter is operating.
2.2.4 LED INDICATORS
Integra-H has four two-color LED indicators. Their functions are shown in Table 2-1.
Table 2-1 LED Color Functions
* Contact technical support.
2.2.5 CONNECTION TO DTE
Integra-H is configured as DCE. Most DTE should be connected using a nine-conductor pin-to-
pin “straight” cable. Some RTUs or PLCs may require a special cable to route the signals correctly. See
the documentation for your data equipment for further information.
2.2.6 COM PORT
Baud rates from 300 to 19200 are supported. Integra's are factory set (default) for 9600 b/s, 8 bits,
no parity, and 1 stop bit. Unless required by your operating protocol, we advise restricting port speed to
be equal to or less than the RF network speed.
RUN/PWR Green Normal operation
Flash green Sleep mode (flashes during wakeup)
Flash red & green Setup mode or loading new application or new bootloader
Flash red Firmware error*
Red CPU or PROM failure*
CS/SYN Off No RF RX carrier
Green Receive carrier present
Red (Reserved)
RX/TX Off No RF RX carrier
Green Receiving network data
Yellow Synthesizer unlocked
Red Transmitter is on
RD/TD Off Idle
Green RX data outgoing from RS-232 port
Red TX data incoming at RS-232 port