User Manual
120 10503-201 PRELIMINARY T-96S Technical Manual6
1.11.4 Network Using T-96H for Online Diagnostics
This configuration has the following characteristics:
• Master station may be half duplex or
simplex.
• Accumulated online diagnostics for a
maximum of 15 stations are available at
a monitoring site (monitoring site must
be in range of all remotes).
• Online diagnostics are available in real
time at the monitoring site.
• Remote offline diagnostics, statistics and
control are available from the monitoring
site by temporarily disabling network
activity.
Online diagnostics are accumulated in the
monitoring T-96H for the last 15 stations
heard. This information may be viewed using
the OFLNDIAG. For larger networks, the T-
96H can output raw diagnostic data only,
which may be interpreted for network man-
agement by the Dataradio ONDMON pro-
gram or by a user-supplied software pro-
gram. Contact your sales representatives for
more information.
PLC
Master
PLC
T96H
T96H
T96H
T96H
PC for online
diagnostics
PLC
Figure 4 - Network with Monitoring Site