User Manual

4-3
Part No. 001-2100-101
PROBLEM
No/Poor Transmit
CHECK
z Verify power supply voltage.
z Verify power supply voltage can source 2000 mA minimum.
z Verify proper programming including frequency and time-out-timer.
z Check system VSWR, feedline loss, connectors, and antenna.
z Check radio output power with wattmeter.
PROBLEM
No/Poor Receive
CHECK
z Verify Power Supply voltage.
z Verify proper receive frequency programming.
z Check feedline loss, connectors and antenna.
z Apply -100 dBm RF signal at antenna connector and check RSSI indicator in User Test utility.
z Verify that the channel is unoccupied.