Spa Owner's Manual
10
Testing the GFCI Breaker
Test  the  GFCI  breaker  prior  to 
rst use and  periodically  when  the 
spa  is  powered.  To  test  the  GFCI 
breaker  follow  these  instructions 
(spa should be operating):
Press  the  TEST  button  on  the 1. 
GFCI.  The GFCI  will trip and 
the spa will shut off.
Reset  the  GFCI  breaker  by 2. 
switching the breaker to the full 
OFF  position,  wait  a  moment, 
then turn the breaker back on. 
The  spa  should  have  power 
again.
Conguring the 6300 
Control System
The 6300 control system requires 
higher power than other 240V sys-
tems. Dip switch #10 is factory set 
in the ON position. This causes the 
heater to shut off when any pump 
is running in high speed. To allow 
the heater to continue operating, 
dip switch #10 must be set to the 
OFF position.
To ensure your spa functions prop-
erly, ensure the following steps are 
performed before starting your spa:
When  installing  the  electrical • 
system,  use  a  60  amp  GFCI. 
Follow the GFCI wiring diagram 
on the next page.
Have  your  dealer  or  installer • 
set  dip  switch  #10  to  the  OFF 
position on the circuit board as 
shown below.