High Elevation Installation
Your replace or re pit is approved for elevations up to 4500 feet in 
the US and Canada.
When installing this appliance at an elevation above 4500 feet in the 
US, it may be necessary to decrease the input rating by changing the 
existing burner orice to a smaller size. Reduce the input by 4% for 
each 1,000 feet above sea level, unless the heating value of the gas 
has been  reduced, in  which  case this  general rule  will not  apply.  To 
identify the proper orice size, check with your local gas utility.
When installing this unit at an elevation above 4,500 feet in Canada 
check with your local authorities. Consult the local gas utility for assis-
tance in determining the proper orice for your location.
Natural Gas Conversion
CAUTION: This service is to be completed only by an authorized gas 
appliance  installer.  Do  not  attempt  this  conversion  on  your  own  as 
there is risk of serious injury or death.
To The Authorized Gas Appliance Installer:
All  Cal  Flame  replaces  and  repits  are  shipped  from  the  factory 
equipped  to  burn  on  liquid  propane  fuel.  Enclosed  with  this  kit  is  a 
natural gas conversion kit  for converting this  unit  to natural gas.  To 
perform this  conversion, follow the directions below and to the local 
regulation standards in your area. 
1.  Make sure unit is not in operation and is cool enough to perform 
this  service.  Shut  off  and disconnect  propane  fuel source  at  the 
regulator end.
2.  Carefully remove the storage cover, lava rocks and re logs. Turn 
unit over to access hose connections underneath. 
3.  While holding the propane orice in place with a wrench, unscrew 
brass tting  on  fuel  inlet  hose.  Unscrew  propane  orice  and  re-
move. 
4.  Using the new brass natural gas orice re-install the parts in the 
same sequence. Turn the protective screen / air intake sleeve to al-
low a controlled amount of air ow through the screen and into the 
fuel supply tube. Flame should have good retention. For a proper 