Specifications
FUNCTION
INDICATOR
LIGHT
HOMEOWNER'S
GUIDE TO THE TROPIC
ISLE HEATER
WITH INDICATOR
LIGHTS
The four
indicator lights are
provided
to.help
you
under-
stand lhe operation
oJ the
heater and
if
something should
.go
wrong, to
help find the
problem.
POWER
LIGHT
The light should
go
on
when
on/off
switch
is
pushed
on.
lf
it doesn't,
check the circuit
breaker or
fuse in
the house
electrical
power
control box.
lf all breakers are on or all
tuses are
good, you
should call-a
qualified
serviceman.
PRESSURE
LIGHT
When
the
power
light is
on
and the
pump
is running,
creating
water
pressure
in the
lines,
the
pressure
light
should
be on. lf the
pressure
light does not come on
when
the
pump
is running, the
pump
may have lost its
prime.
lf
this
is not the case,
water flow may be
restricted by an in-
advertently
closed
valve or a clogged
filter
or
pump
basket.
HEAT LIGHT
& HI.LIMIT LIGHT
Whenever the
pressure
lighl
is
on
and the thermosiat
is sei
to
call for heating, the
heat light
will normally come on
and
heating ot
the
water will occur,
(when
the
gas
valve knob is
in
the
"On"
oosition).
When the
water has
reached the
desired lemperature
the
heat
light will
go
out,
water
heating
will stop.
lf
the
hi-limit light comes
on
instead of
the heat
light, it
indicales that the high
limit thermoslats
have been
activated due
io an over
heating condition.
Check
for closed
valves, a dirty
filter,
or
a clogged
pump
basket that could
prevent
water flow.
Another
problem
that
can cause the
high limit thermostats
to trip,
is a defective
temoerature
control thermostat.
To check
tor this, turn the
temperature
control
knob to
lhe
cold
position.
lf the heat
light and the
hi-limit
light do not
go
olf,
the thermoslat
is
defective.
lf over heating
has occurred,
correct the
flow
problem
as soon as
waler temperature
in the
heat ex'
changer
is sufficiehtly
cooled.
The high limit thermostat
will automatically
reset itself.
o
o
o
o
POWER PRESSURE
HEAT HI.LIMIT
Fig. !0
SPECIFICATIONS
STACK
MODEL
STACKLESS
MODEL
-
I
I
31U,
I
I
t
12
__L
l---."-!
,,n',
l-
HEATER
SPECIFICATIONS
Model
c120
c t80 c240 c300
c360 c400
''A"
Width
(Front) 16Y2" 2O'/2"
231/2" 2a'/2" 321/2"
36v2"
"8"
Lelt Side to
g
Stack
9"
11'
121/," 15"
19"
"C"
Height
{wiDrafthood)
6OY," 601/2"
61'/2" 62tL"
65'/2"
R
=
GAS LINE HOLE