Use and Care Manual
18
Installation / Assembly
Fire Pit Owner’s Manual
LTR50001010, Rev. M
High Elevation Installation
Your replace or re pit is approved for elevations up to 4500 feet in 
the US and Canada.
When installing this appliance at an elevation above 4500 feet in the 
US, it may be necessary to decrease the input rating by changing the 
existing burner orice to a smaller size. Reduce the input by 4% for 
each 1,000 feet above sea level, unless the heating value of the gas 
has been reduced, in which case this general rule will not apply. To 
identify the proper orice size, check with your local gas utility.
When installing this unit at an elevation above 4,500 feet in Canada 
check with your local authorities. Consult the local gas utility for assis-
tance in determining the proper orice for your location.
Natural Gas Conversion
CAUTION: This service is to be completed only by an autho-
rized gas appliance installer. Do not attempt this conversion 
on your own as there is risk of serious injury or death.
To The Authorized Gas Appliance Installer:
All  Cal  Flame  replaces  and  repits  are  shipped  from  the  factory 
equipped to burn on liquid propane fuel. Enclosed with this kit is a 
natural gas conversion kit for converting this unit to natural gas. To 
perform this conversion, follow the directions below and to the local 
regulation standards in your area. 
1.  Make sure unit is not in operation and is cool enough to perform 
this service. Shut off and disconnect propane fuel source at the 
regulator end.
2.  Carefully remove the lava rocks and re logs. Turn unit over to ac-
cess hose connections underneath. 
3.  While holding the propane orice in place with a wrench, unscrew 
brass tting  on  fuel  inlet  hose.  Unscrew propane  orice  and  re-
move. 
Components