Use and Care Manual
18 49-2000061  Rev. 2
INSTALLATION INSTRUCTIONS
Installation Instructions
7
 INSTALL MOTOR
•  Align and engage the 
slots in the blower 
assembly to the 3 
hooks at the rear of the 
exhaust opening.
•  Rotate motor upwards 
until it aligns with the 
attachment screw 
location.
•  Secure the motor to 
attachment bracket 
at the front of the 
opening with washer 
and screw provided.
•  Plug the motor connector into the 
mating hood connector. Seethe 
illustration for the hood 
connector location. Touch 
the hood to locate and make the 
connection.
IMPORTANT: Hold the connector 
so the two square corner terminals 
are at the top as you position the 
connector to plug it in.
9
 INSTALL DUCT COVERS
To install the 12” duct cover alone:
•  Place the 12” section of the decorative duct cover 
on top of the hood.
•  Secure the cover on the top of the hood with 4 
screws provided.
To install the 2-piece duct cover:
•  Place the 2-piece duct cover on the top of the hood.
•  Secure the bottom cover to the top of the hood 
with 4 screws provided. See illustration, page 16.
•  Extend the inside section upwards to meet the 
ceiling and ceiling bracket
•  Secure the duct cover to the bracket with the 2 
small Phillips screws provided.
10
 INSTALL FILTER SUPPORT
•  Tip filter support into the rear of the hood.
•  Insert support tabs into the slots at the rear of the 
hood.
•  Secure the support to the hood with screws as 
shown.
8
 CONNECT ELECTRICAL
Verify that power is turned off at the source.
WARNING
 If house wiring is not 2-wire with 
a ground wire, a ground must be provided by the 
installer. When house wiring is aluminum, be sure 
to use UL approved anti-oxidant compound and 
aluminum-to-copper connectors.
•  Use wire nuts to connect incoming ground to 
green, white to white, and black to black.
•  Push wires into junction box and replace cover. 
Be sure wires are not pinched.
Motor Attachment 
Bracket
Motor Hooks
Ground
A Remove 
Junction 
Box Cover
B Check that White, Black 
and Green Hood Wires 
are Threaded thru Small 
Hole in Bracket.
D Use UL Listed Wire Nuts
C Insert Power 
Conduit thru 
Strain Relief 
and Tighten
Black
White
Insert Tabs into Slots
Install 2 Screws