Specification Guide
Café Minimal Series 30" Smart Built-In
Twin Flex Single Wall Oven in Platinum Glass
CTS92DM2NS5
WARRANTY
Parts warranty Limited 1-year entire appliance
Labor warranty Limited 1-year entire appliance
Warranty notes See written warranty for full details
MOST 30" WALL CABINETS CAN BE USED WITH
THIS UNIT.
APPROVED INSTALLATIONS:
Above Warming Drawer, Below Built-in Microwave or Advantium®,
Side-by Side, and Under Counter
NOTE: These ovens are not approved for stacking one single wall
oven over another single wall oven.
Cabinets installed adjacent to wall ovens must have an adhesion
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets and drawers on
adjacent 45° and 90° walls should be placed to avoid interference
with the handle.
Side-by-side installations rerquire at least 2" between cutouts.
Approved cooktops for installation above this wall oven: CHP9536,
PHP9036, CHP9530, PHP9030, JP3536, JP3036, JP3530, JP3030
IMPORTANT: Electric wall ovens are not approved for installation
with a plug and receptacle. They must be hard wired in accordance
with installation instructions.
IMPORTANT: Before installing, consult installation instructions
packed with product for MOST 30" WALL CABINETS CAN BE
USED WITH THIS UNIT.
APPROVED INSTALLATIONS: Above Warming Drawer, Below Built-
in Microwave or Advantium®, Side-by Side, and Under Counter
NOTE: These ovens are not approved for stacking one single wall
oven over another single wall oven.
Cabinets installed adjacent to wall ovens must have an adhesion
spec of at least a 200°F temperature rating.
Door handle protrudes 3" from door face. Cabinets and drawers on
adjacent 45° and 90° walls should be placed to avoid interference
with the handle.
Side-by-side installations require at least 2" between cutouts.
Approved cooktops for installation above this wall oven: CHP9536,
PHP9036, CHP9530, PHP9030, JP3536, JP3036, JP3530, JP3030
IMPORTANT: Electric wall ovens are not approved for installation
with a plug and receptacle. They must be hard wired in accordance
with installation instructions.
IMPORTANT: Before installing, consult installation instructions
packed with product for current dimensional data.
Junction Box
Location, Right
Hand Side Only
(may be located in
Adjacent Cabinet)
22" (55.9 cm) min.
to Bottom of
Junction Box
Cutout Depth
23-1/2" (59.7 cm) min.
Open Door Clearance
15" (38.1 cm) min.
NOTE: Opening
Between Inside
Walls Must be at
Least
28-1/2"
(72.4 cm) wide
NOTE: Allow
1/4" (0.7 cm)
clearances from
side edges of
oven door
Junction Box Location
9-1/2" (24.1 cm) max.
Recommended Cutout
Location from Floor
26-1/2" (67.3 cm) max.
Cutout Height
27 5/16" (69.4) max.
27 1/4" (69.2) min.
21-1/2"
Cutout Width
28 5/8" (72.7) max.
28 1/2" (72.4) min
.
Junction Box Location, Right Hand Side Only
(may be located in Adjacent Cabinet)
15" min.
Open Door Clearance
11/16" (1.8) min.
Clearance for Wall Oven Beyond
Cutout, Both Sides
NOTE: Allow 1/4" (0.7)
clearances from side edges of
oven door
Suggested Cutout Location
from Floor26-1/2" (67.3)
Cabinet 30"
A - Overlap of oven at top of cutout 1"
B - Overlap of oven other side of edge of cutout 3/4"
C - Overlap of oven at bottom of cutout 1-1/4"
Oven
D - Install depth 23-1/2"
E - Overall height with trim 53"
F - Overall width 29-3/4"
9-1/2" MAX.
F
Conduit
48"
47" to
bottom of
junction box
Junction box
location
Cutout depth
23-1/2" MIN
B
21"
22" minimum
door opening
allowance
E
D
2 x 4 or
equivalent runners
level with bottom of cutout
and flush with sides of cutout
or solid bottom floor.
Suitable
bracing
to support
runners
(must support 400 lbs.)
C
L
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
Cutout height
50-1/4" MIN.
without pedestal
51-13/16" MIN.
51-15/16" MAX.
with pedestal
Recommended
minimum
cutout location
from the floor
12"
30''
CTD70DM2NS5, CTD70DP2NS1, CTD90DM2NS5,
CTD90DP2NS1, CTD90DP3ND1, CTD90DP4NW2
Cabinet 30"
A - Overlap of oven at top of cutout 1"
B - Overlap of oven other side of edge of cutout 3/4"
C - Overlap of oven at bottom of cutout 1-1/4"
Oven
D - Install depth 23-1/2"
E - Overall height with trim 53"
F - Overall width 29-3/4"
9-1/2" MAX.
F
Conduit
48"
47" to
bottom of
junction box
Junction box
location
Cutout depth
23-1/2" MIN
B
21"
22" minimum
door opening
allowance
E
D
2 x 4 or
equivalent runners
level with bottom of cutout
and flush with sides of cutout
or solid bottom floor.
Suitable
bracing
to support
runners
(must support 400 lbs.)
C
L
Cutout width
28-1/2" MIN.
28-5/8" MAX.
B
A
C
Cutout height
50-1/4" MIN.
without pedestal
51-13/16" MIN.
51-15/16" MAX.
with pedestal
Recommended
minimum
cutout location
from the floor
12"
30''
CTD70DM2NS5, CTD70DP2NS1, CTD90DM2NS5,
CTD90DP2NS1, CTD90DP3ND1, CTD90DP4NW2
Dimension and installation information are shown in inches.
For answers to your Café™ product questions, visit our website at cafeappliances.com.
© 2020 GE Appliances PC94987 09/20
28-5/8" (72.7) max.
28-1/2" (72.4) min.
1" (2.4) min.
Top Clearance
for Wall Oven
Beyond Cutout
1-1/4" (3.2) min.
Bottom Clearance
for Wall Oven
Beyond Cutout
Cutout Width
Cabinet Width
27-5/16" (69.4) max.
27-1/4" (69.2) min.
Cutout Width
26-1/2" (67.3)
Suggested Cutout
Location from Floor
31-1/4" min.
From top surface
of countertop to
top surface of
wall oven support
platform
2-1/2" min.
From front surface
of cabinet to front edge
of cooktop cutout
30"
Center Line Center Line
11/16" (1.8) min.
Clearance for Wall
Oven Beyond
Cutout, Both Sides
Cutout - observe
all dimensions and
requirements
Cutout - observe
all dimensions and
requirements
30-1/2" (77.5) min.
30" models
2" (5.1) min.
Junction Box
Location, Right
Hand Side Only
(may be located in
Adjacent Cabinet)
22" (55.9) min.
to Bottom of
Junction Box
23-1/2" (59.7) min.
Cutout Depth
15" (38.1) min.
Open Door Clearance
NOTE: Opening
Between Inside
Walls Must be at
Least
28-1/2"
(72.4) wide
NOTE: Allow
1/4" (0.7)
clearances from
side edges of
oven door
9-1/2" (24.1) max.